线路建模方法对多地配电馈线中性点对地电压分析的影响

R. Horton, W. Sunderman, R. Arritt, R. Dugan
{"title":"线路建模方法对多地配电馈线中性点对地电压分析的影响","authors":"R. Horton, W. Sunderman, R. Arritt, R. Dugan","doi":"10.1109/PSCE.2011.5772574","DOIUrl":null,"url":null,"abstract":"Accurate determination of neutral-to-earth voltages (NEV) in multi-grounded distribution circuits can be quite important, particularly in systems where loads are highly unbalanced or have considerable triplen harmonic current content. Some commercially-available and open source software are capable of representing distribution systems in adequate detail for performing NEV analysis. However, results can vary among programs depending on how the distribution line and associated grounding systems are modeled. This paper describes ways to model distribution lines and grounding systems to perform NEV analysis focusing on the earth return model. A simple test feeder is used to show how different distribution line and grounding system models affect NEV analysis.","PeriodicalId":120665,"journal":{"name":"2011 IEEE/PES Power Systems Conference and Exposition","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Effect of line modeling methods on neutral-to-earth voltage analysis of multi-grounded distribution feeders\",\"authors\":\"R. Horton, W. Sunderman, R. Arritt, R. Dugan\",\"doi\":\"10.1109/PSCE.2011.5772574\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate determination of neutral-to-earth voltages (NEV) in multi-grounded distribution circuits can be quite important, particularly in systems where loads are highly unbalanced or have considerable triplen harmonic current content. Some commercially-available and open source software are capable of representing distribution systems in adequate detail for performing NEV analysis. However, results can vary among programs depending on how the distribution line and associated grounding systems are modeled. This paper describes ways to model distribution lines and grounding systems to perform NEV analysis focusing on the earth return model. A simple test feeder is used to show how different distribution line and grounding system models affect NEV analysis.\",\"PeriodicalId\":120665,\"journal\":{\"name\":\"2011 IEEE/PES Power Systems Conference and Exposition\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE/PES Power Systems Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PSCE.2011.5772574\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE/PES Power Systems Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PSCE.2011.5772574","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

摘要

在多地配电电路中,准确测定中性对地电压(NEV)是非常重要的,特别是在负载高度不平衡或具有相当大的三次谐波电流含量的系统中。一些商业上可用的和开放源码的软件能够充分详细地表示分配系统,以执行新能源汽车分析。然而,根据如何对配电线路和相关接地系统进行建模,不同程序的结果可能有所不同。本文介绍了对配电线路和接地系统进行新能源汽车分析的建模方法,重点介绍了接地回归模型。用一个简单的试验馈线来说明不同的配电线路和接地系统模型对新能源汽车分析的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of line modeling methods on neutral-to-earth voltage analysis of multi-grounded distribution feeders
Accurate determination of neutral-to-earth voltages (NEV) in multi-grounded distribution circuits can be quite important, particularly in systems where loads are highly unbalanced or have considerable triplen harmonic current content. Some commercially-available and open source software are capable of representing distribution systems in adequate detail for performing NEV analysis. However, results can vary among programs depending on how the distribution line and associated grounding systems are modeled. This paper describes ways to model distribution lines and grounding systems to perform NEV analysis focusing on the earth return model. A simple test feeder is used to show how different distribution line and grounding system models affect NEV analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Testing the “smarts” in the smart T & D grid Similarity measures in Small World Stratification for distribution fault diagnosis Market-based transmission expansion planning Customer-centered control system for intelligent and green building with heuristic optimization Concepts of FACTS controllers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1