[使用kt1000关节计测量膝关节松动程度]。

L Gáspár, I Kiss, C Farkas, I Lampé, K Szepesi
{"title":"[使用kt1000关节计测量膝关节松动程度]。","authors":"L Gáspár,&nbsp;I Kiss,&nbsp;C Farkas,&nbsp;I Lampé,&nbsp;K Szepesi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Authors measured the stability in the sagittal plane of the intact knee joints of 50 young men with the MEDmetric KT 1000 apparatus. The greatest movement during the measurements on 100 knees was observed in 25 degrees flexion and during the application of force 89N. In 70 degrees flexion the movement was only half of that observed in 25 degrees flexion. The difference of the average movements measured bilaterally was neither in active nor in passive experiments more than 0.5 mm. The difference between the average values of the compliance indexes on the left and right side was only 0.01 mm. In all measurements the frequency distribution of the differences between the two sides was essentially the same. The difference between the movements on the two sides did not exceed 2 mm-s in 90-100 percent of the cases.</p>","PeriodicalId":74098,"journal":{"name":"Magyar traumatologia, orthopaedia es helyreallito sebeszet","volume":"35 3","pages":"245-54"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Measuring the looseness of the knee joint by using the Kt 1000 arthrometer].\",\"authors\":\"L Gáspár,&nbsp;I Kiss,&nbsp;C Farkas,&nbsp;I Lampé,&nbsp;K Szepesi\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Authors measured the stability in the sagittal plane of the intact knee joints of 50 young men with the MEDmetric KT 1000 apparatus. The greatest movement during the measurements on 100 knees was observed in 25 degrees flexion and during the application of force 89N. In 70 degrees flexion the movement was only half of that observed in 25 degrees flexion. The difference of the average movements measured bilaterally was neither in active nor in passive experiments more than 0.5 mm. The difference between the average values of the compliance indexes on the left and right side was only 0.01 mm. In all measurements the frequency distribution of the differences between the two sides was essentially the same. The difference between the movements on the two sides did not exceed 2 mm-s in 90-100 percent of the cases.</p>\",\"PeriodicalId\":74098,\"journal\":{\"name\":\"Magyar traumatologia, orthopaedia es helyreallito sebeszet\",\"volume\":\"35 3\",\"pages\":\"245-54\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magyar traumatologia, orthopaedia es helyreallito sebeszet\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magyar traumatologia, orthopaedia es helyreallito sebeszet","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

作者用MEDmetric KT 1000仪器测量了50名年轻男性完整膝关节矢状面稳定性。在100个膝盖的测量中,最大的运动是在25度弯曲和施加89N的力时观察到的。在70度屈曲中,运动仅为25度屈曲的一半。在主动和被动实验中,双侧测量的平均运动差异均不超过0.5 mm。左右侧顺应性指标平均值相差仅0.01 mm。在所有的测量中,两边差异的频率分布基本上是相同的。在90- 100%的病例中,两侧运动之间的差异不超过2 mm-s。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Measuring the looseness of the knee joint by using the Kt 1000 arthrometer].

Authors measured the stability in the sagittal plane of the intact knee joints of 50 young men with the MEDmetric KT 1000 apparatus. The greatest movement during the measurements on 100 knees was observed in 25 degrees flexion and during the application of force 89N. In 70 degrees flexion the movement was only half of that observed in 25 degrees flexion. The difference of the average movements measured bilaterally was neither in active nor in passive experiments more than 0.5 mm. The difference between the average values of the compliance indexes on the left and right side was only 0.01 mm. In all measurements the frequency distribution of the differences between the two sides was essentially the same. The difference between the movements on the two sides did not exceed 2 mm-s in 90-100 percent of the cases.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Epidural Hematoma [Early synovectomy in the treatment of juvenile rheumatoid arthritis]. [Abdominal injuries in polytraumatised patients]. [Results of sonographic hip examination of infants in a risk group]. [Ultrasonic examination of soft tissue injuries in the shoulder region].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1