原子分辨率的三维晶体重建。

Scanning microscopy. Supplement Pub Date : 1992-01-01
K H Downing
{"title":"原子分辨率的三维晶体重建。","authors":"K H Downing","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Three-dimensional structures have recently been determined by electron crystallography at a resolution high enough to determine atomic arrangements in both protein and mineral specimens. The different nature of these two types of specimens produces some very significant differences in the way data is obtained and processed, although the principles are the same. The sensitivity of proteins to damage by the electron beam limits the signal-to-noise ratio in the image and the resolution to which data can be extracted from the image. A number of constraints, such as the amino acid sequence and the connectivity of atoms within amino acids, can be used in interpreting the limited image data. In materials samples, the relative insensitivity to damage allows obtaining resolution limited only by the microscope. In many samples, dynamical scattering and other non-linear effects limit the information in the image, but this limit can be circumvented by working in very thin areas of the specimen.</p>","PeriodicalId":77379,"journal":{"name":"Scanning microscopy. Supplement","volume":"6 ","pages":"43-52"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three-dimensional crystallographic reconstruction for atomic resolution.\",\"authors\":\"K H Downing\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Three-dimensional structures have recently been determined by electron crystallography at a resolution high enough to determine atomic arrangements in both protein and mineral specimens. The different nature of these two types of specimens produces some very significant differences in the way data is obtained and processed, although the principles are the same. The sensitivity of proteins to damage by the electron beam limits the signal-to-noise ratio in the image and the resolution to which data can be extracted from the image. A number of constraints, such as the amino acid sequence and the connectivity of atoms within amino acids, can be used in interpreting the limited image data. In materials samples, the relative insensitivity to damage allows obtaining resolution limited only by the microscope. In many samples, dynamical scattering and other non-linear effects limit the information in the image, but this limit can be circumvented by working in very thin areas of the specimen.</p>\",\"PeriodicalId\":77379,\"journal\":{\"name\":\"Scanning microscopy. Supplement\",\"volume\":\"6 \",\"pages\":\"43-52\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scanning microscopy. Supplement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scanning microscopy. Supplement","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

最近,三维结构已被电子晶体学确定,其分辨率足以确定蛋白质和矿物标本中的原子排列。尽管原理相同,但这两种类型标本的不同性质在数据获取和处理方式上产生了一些非常显著的差异。蛋白质对电子束损伤的敏感性限制了图像中的信噪比和从图像中提取数据的分辨率。许多限制,如氨基酸序列和氨基酸内原子的连通性,可用于解释有限的图像数据。在材料样品中,对损伤的相对不敏感使得只能通过显微镜才能获得分辨率。在许多样品中,动态散射和其他非线性效应限制了图像中的信息,但可以通过在样品的非常薄的区域进行工作来绕过这一限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Three-dimensional crystallographic reconstruction for atomic resolution.

Three-dimensional structures have recently been determined by electron crystallography at a resolution high enough to determine atomic arrangements in both protein and mineral specimens. The different nature of these two types of specimens produces some very significant differences in the way data is obtained and processed, although the principles are the same. The sensitivity of proteins to damage by the electron beam limits the signal-to-noise ratio in the image and the resolution to which data can be extracted from the image. A number of constraints, such as the amino acid sequence and the connectivity of atoms within amino acids, can be used in interpreting the limited image data. In materials samples, the relative insensitivity to damage allows obtaining resolution limited only by the microscope. In many samples, dynamical scattering and other non-linear effects limit the information in the image, but this limit can be circumvented by working in very thin areas of the specimen.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Nucleic acid detection by in situ molecular immunogold labeling procedures. Hydration-scanning tunneling microscopy as a reliable method for imaging biological specimens and hydrophilic insulators. Imaging molecular structure of channels and receptors with an atomic force microscope. Atomic force microscopy of DNA, nucleoproteins and cellular complexes: the use of functionalized substrates. Microscopic analysis of DNA and DNA-protein assembly by transmission electron microscopy, scanning tunneling microscopy and scanning force microscopy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1