V. Bolgov, K. Janson, J. Šklovski, I. Palu, M. Laanetu
{"title":"风力发电对萨雷马Sõrve半岛电网运行的影响","authors":"V. Bolgov, K. Janson, J. Šklovski, I. Palu, M. Laanetu","doi":"10.1109/PQ.2012.6256223","DOIUrl":null,"url":null,"abstract":"There is rapidly increasing wind generation capacity in Estonia. The main wind areas are located near sea coastal line where wind parks can often be connected only to relatively weak medium-voltage distribution power grids. The aim region of investigation was wind-rich Sõrve peninsula of Saaremaa island. The impact of existing wind farms on levels of voltages, losses and consumption has been preliminarily investigated. A way to decrease voltage deviations has been proposed.","PeriodicalId":185013,"journal":{"name":"2012 Electric Power Quality and Supply Reliability","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Wind power generation impact on Sõrve peninsula network operation in Saaremaa\",\"authors\":\"V. Bolgov, K. Janson, J. Šklovski, I. Palu, M. Laanetu\",\"doi\":\"10.1109/PQ.2012.6256223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There is rapidly increasing wind generation capacity in Estonia. The main wind areas are located near sea coastal line where wind parks can often be connected only to relatively weak medium-voltage distribution power grids. The aim region of investigation was wind-rich Sõrve peninsula of Saaremaa island. The impact of existing wind farms on levels of voltages, losses and consumption has been preliminarily investigated. A way to decrease voltage deviations has been proposed.\",\"PeriodicalId\":185013,\"journal\":{\"name\":\"2012 Electric Power Quality and Supply Reliability\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Electric Power Quality and Supply Reliability\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PQ.2012.6256223\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Electric Power Quality and Supply Reliability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PQ.2012.6256223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Wind power generation impact on Sõrve peninsula network operation in Saaremaa
There is rapidly increasing wind generation capacity in Estonia. The main wind areas are located near sea coastal line where wind parks can often be connected only to relatively weak medium-voltage distribution power grids. The aim region of investigation was wind-rich Sõrve peninsula of Saaremaa island. The impact of existing wind farms on levels of voltages, losses and consumption has been preliminarily investigated. A way to decrease voltage deviations has been proposed.