根据尼日利亚东南部Ikeduru垂直电测深(VES)估算的水力参数评价地下水供应潜力

Nwosu Jacinta Chiemela, L. Nwosu, G. Chukwu
{"title":"根据尼日利亚东南部Ikeduru垂直电测深(VES)估算的水力参数评价地下水供应潜力","authors":"Nwosu Jacinta Chiemela, L. Nwosu, G. Chukwu","doi":"10.14419/IJAG.V7I1.16539","DOIUrl":null,"url":null,"abstract":"A Vertical Electrical resistivity Sounding (VES) survey was carried out, to study the groundwater supply potential, protective capacity and soil corrosivity of aquifers in Ikeduru Local Government Area of Imo state, Nigeria. A total of ten (10) geoelectric soundings were acquired. Schlumberger electrode configuration was used in acquiring the data. Six to seven geoelectric layers were delineated from the interpreted results, the Aquifers were delineated between the fifth and sixth geoelectric layers, having an apparent resistivity above 1000Ωm, with the highest thick of 69.0m at a depth of 144.0m. Longitudinal Conductance, Hydraulic Conductivity, Transmissivity and Product Conductance range are as followings for the aquifers; 1.720 – 127.000 x 10-3Ω-1, 15.90 – 188.79m/day, 1093.3 – 1097.1m2/day and 2.590 – 252.50 x 10-3 respectively. Inferring from our hydraulic parameters, all the aquiferous zones have very high designation, wwithdrawal of great regional importance of groundwater supply potential and practically noncorrosive, soil corrosivity. 40% percentage of the aquiferous units have very good protective capacity, while for excellent and good protective capacity of the study are is 30%. All the VES points are said to be a very viable potential for safe source for groundwater exploration.  ","PeriodicalId":424421,"journal":{"name":"International Journal of Advanced Geosciences","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of groundwater supply potential from hydraulic parameters estimated from vertical electrical sounding (VES) in Ikeduru, south east Nigeria\",\"authors\":\"Nwosu Jacinta Chiemela, L. Nwosu, G. Chukwu\",\"doi\":\"10.14419/IJAG.V7I1.16539\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A Vertical Electrical resistivity Sounding (VES) survey was carried out, to study the groundwater supply potential, protective capacity and soil corrosivity of aquifers in Ikeduru Local Government Area of Imo state, Nigeria. A total of ten (10) geoelectric soundings were acquired. Schlumberger electrode configuration was used in acquiring the data. Six to seven geoelectric layers were delineated from the interpreted results, the Aquifers were delineated between the fifth and sixth geoelectric layers, having an apparent resistivity above 1000Ωm, with the highest thick of 69.0m at a depth of 144.0m. Longitudinal Conductance, Hydraulic Conductivity, Transmissivity and Product Conductance range are as followings for the aquifers; 1.720 – 127.000 x 10-3Ω-1, 15.90 – 188.79m/day, 1093.3 – 1097.1m2/day and 2.590 – 252.50 x 10-3 respectively. Inferring from our hydraulic parameters, all the aquiferous zones have very high designation, wwithdrawal of great regional importance of groundwater supply potential and practically noncorrosive, soil corrosivity. 40% percentage of the aquiferous units have very good protective capacity, while for excellent and good protective capacity of the study are is 30%. All the VES points are said to be a very viable potential for safe source for groundwater exploration.  \",\"PeriodicalId\":424421,\"journal\":{\"name\":\"International Journal of Advanced Geosciences\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Advanced Geosciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14419/IJAG.V7I1.16539\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Advanced Geosciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14419/IJAG.V7I1.16539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了研究尼日利亚伊莫州Ikeduru地方政府地区含水层的地下水供应潜力、保护能力和土壤腐蚀性,开展了垂直电阻率测深(VES)调查。共进行了10次地电测深。数据采集采用斯伦贝谢电极结构。根据解释结果圈定了6 ~ 7个地电层,在第5 ~ 6个地电层之间圈定了含水层,视电阻率在1000Ωm以上,在144.0m深度处最大厚度为69.0m。含水层的纵向电导率、水力电导率、透过率和积电导率范围如下:分别为1.720 - 127.000 × 10-3Ω-1, 15.90 - 188.79m/天,1093.3 - 1097.1m2/天和2.590 - 252.50 × 10-3。从我们的水力参数推断,所有含水区都具有很高的指示性,地下水供应潜力具有很大的区域重要性,实际上没有腐蚀性,土壤腐蚀性。40%的含水单元具有非常好的保护能力,而本研究中具有优异和良好保护能力的含水单元为30%。所有的地震监测点都被认为是一个非常可行的潜在的地下水勘探安全来源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of groundwater supply potential from hydraulic parameters estimated from vertical electrical sounding (VES) in Ikeduru, south east Nigeria
A Vertical Electrical resistivity Sounding (VES) survey was carried out, to study the groundwater supply potential, protective capacity and soil corrosivity of aquifers in Ikeduru Local Government Area of Imo state, Nigeria. A total of ten (10) geoelectric soundings were acquired. Schlumberger electrode configuration was used in acquiring the data. Six to seven geoelectric layers were delineated from the interpreted results, the Aquifers were delineated between the fifth and sixth geoelectric layers, having an apparent resistivity above 1000Ωm, with the highest thick of 69.0m at a depth of 144.0m. Longitudinal Conductance, Hydraulic Conductivity, Transmissivity and Product Conductance range are as followings for the aquifers; 1.720 – 127.000 x 10-3Ω-1, 15.90 – 188.79m/day, 1093.3 – 1097.1m2/day and 2.590 – 252.50 x 10-3 respectively. Inferring from our hydraulic parameters, all the aquiferous zones have very high designation, wwithdrawal of great regional importance of groundwater supply potential and practically noncorrosive, soil corrosivity. 40% percentage of the aquiferous units have very good protective capacity, while for excellent and good protective capacity of the study are is 30%. All the VES points are said to be a very viable potential for safe source for groundwater exploration.  
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Urbanization-induced geo-environmental changes in Naogaon municipality, Bangladesh: a comprehensive assessment Mapping land surface temperature in Nigeria using Modis data Assessment of vegetation health index (VHI) using Modis data in rivers state, Nigeria Petrogenesis of metaluminous and peraluminous granitoids from Garga-Sarali zone : evidence of I- and S-type sources (central African fold belt in Cameroon) The Petrography and geochemistry of iron-bearing units from Mingo’o area (Ntem complex, southern Cameroon)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1