{"title":"双重(交换输血-碳清除)模型用于检测复苏后网状内皮功能。","authors":"H W Kim,&nbsp;F Chen,&nbsp;A G Greenburg","doi":"10.3109/10731199209119718","DOIUrl":null,"url":null,"abstract":"<p><p>A double exchange transfusion-double carbon clearance method was evaluated for assessing reticuloendothelial (RE) function following exchange transfusion with hemoglobin solutions. Fifty percent of estimated blood volume (3% body weight) was withdrawn from anesthetized Sprague-Dawley rats and isovolumically replaced with shed blood (SB, control), lysed shed blood (LB, pos. control), human stroma-free hemoglobin solution (SFH), or polyhemoglobin solution (PHS). Thirty minutes after the exchange transfusion, colloidal carbon was injected intravenously and its vascular clearance followed for 1 hour. Then, the 50% exchange transfusion was repeated and the second carbon clearance measured. The intravascular carbon clearance constants, K, and clearance half-times, T1/2, were calculated and compared. No apparent differences in RE function were seen among the groups after the initial exchange transfusion. However, following the second exchange transfusion significant (P less than 0.05) slowing of carbon clearance was observed in lysed blood treated animals. The RE function of SFH or PHS treated animals were not different (P less than 0.05) from that of SB animals. A double exchange transfusion-double carbon clearance method seems to reveal changes in RE function that are not apparent after a single exchange transfusion and clearance test.</p>","PeriodicalId":77039,"journal":{"name":"Biomaterials, artificial cells, and immobilization biotechnology : official journal of the International Society for Artificial Cells and Immobilization Biotechnology","volume":"20 2-4","pages":"777-9"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731199209119718","citationCount":"2","resultStr":"{\"title\":\"A double (exchange transfusion-carbon clearance) model for testing post-resuscitation reticuloendothelial function.\",\"authors\":\"H W Kim,&nbsp;F Chen,&nbsp;A G Greenburg\",\"doi\":\"10.3109/10731199209119718\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A double exchange transfusion-double carbon clearance method was evaluated for assessing reticuloendothelial (RE) function following exchange transfusion with hemoglobin solutions. Fifty percent of estimated blood volume (3% body weight) was withdrawn from anesthetized Sprague-Dawley rats and isovolumically replaced with shed blood (SB, control), lysed shed blood (LB, pos. control), human stroma-free hemoglobin solution (SFH), or polyhemoglobin solution (PHS). Thirty minutes after the exchange transfusion, colloidal carbon was injected intravenously and its vascular clearance followed for 1 hour. Then, the 50% exchange transfusion was repeated and the second carbon clearance measured. The intravascular carbon clearance constants, K, and clearance half-times, T1/2, were calculated and compared. No apparent differences in RE function were seen among the groups after the initial exchange transfusion. However, following the second exchange transfusion significant (P less than 0.05) slowing of carbon clearance was observed in lysed blood treated animals. The RE function of SFH or PHS treated animals were not different (P less than 0.05) from that of SB animals. A double exchange transfusion-double carbon clearance method seems to reveal changes in RE function that are not apparent after a single exchange transfusion and clearance test.</p>\",\"PeriodicalId\":77039,\"journal\":{\"name\":\"Biomaterials, artificial cells, and immobilization biotechnology : official journal of the International Society for Artificial Cells and Immobilization Biotechnology\",\"volume\":\"20 2-4\",\"pages\":\"777-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10731199209119718\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomaterials, artificial cells, and immobilization biotechnology : official journal of the International Society for Artificial Cells and Immobilization Biotechnology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10731199209119718\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials, artificial cells, and immobilization biotechnology : official journal of the International Society for Artificial Cells and Immobilization Biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731199209119718","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

采用双交换输注-双碳清除法评估血红蛋白溶液交换输注后网状内皮(RE)功能。从麻醉的Sprague-Dawley大鼠中抽取估计血容量的50%(体重的3%),并等量替换为血(SB,对照组)、溶血(LB, poss,对照组)、人无基质血红蛋白溶液(SFH)或多血红蛋白溶液(PHS)。换血30分钟后静脉注射胶体碳,随访1小时血管清除率。然后,重复50%的交换输血,并测量第二次碳清除率。计算并比较了血管内碳清除常数K和清除半衰期T1/2。初次换血后各组间肾功能无明显差异。然而,在第二次换血后,经解血处理的动物的碳清除速度显著减慢(P < 0.05)。SFH和PHS处理动物的RE功能与SB处理动物无显著差异(P < 0.05)。双交换输注-双碳清除方法似乎揭示了在单次交换输注和清除试验后不明显的RE功能变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A double (exchange transfusion-carbon clearance) model for testing post-resuscitation reticuloendothelial function.

A double exchange transfusion-double carbon clearance method was evaluated for assessing reticuloendothelial (RE) function following exchange transfusion with hemoglobin solutions. Fifty percent of estimated blood volume (3% body weight) was withdrawn from anesthetized Sprague-Dawley rats and isovolumically replaced with shed blood (SB, control), lysed shed blood (LB, pos. control), human stroma-free hemoglobin solution (SFH), or polyhemoglobin solution (PHS). Thirty minutes after the exchange transfusion, colloidal carbon was injected intravenously and its vascular clearance followed for 1 hour. Then, the 50% exchange transfusion was repeated and the second carbon clearance measured. The intravascular carbon clearance constants, K, and clearance half-times, T1/2, were calculated and compared. No apparent differences in RE function were seen among the groups after the initial exchange transfusion. However, following the second exchange transfusion significant (P less than 0.05) slowing of carbon clearance was observed in lysed blood treated animals. The RE function of SFH or PHS treated animals were not different (P less than 0.05) from that of SB animals. A double exchange transfusion-double carbon clearance method seems to reveal changes in RE function that are not apparent after a single exchange transfusion and clearance test.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Polysaccharide microcapsules and macroporous beads for enhanced chromatographic separation. Polydisperse dextran as a diffusing test solute to study the membrane permeability of alginate polylysine microcapsules. Inhibition of endotoxin-mediated activation of endothelial cells by a perfluorocarbon emulsion. Proceedings of the 2nd Bioencapsulation Research Group Workshop. Cachan, France, April 6-8, 1992. The use of semifluorinated alkanes in blood-substitutes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1