阻尼电路对多相同步发电机馈入多个整流器性能影响的实验评估

M. Mezzarobba, Luca Spangaro, A. Tessarolo
{"title":"阻尼电路对多相同步发电机馈入多个整流器性能影响的实验评估","authors":"M. Mezzarobba, Luca Spangaro, A. Tessarolo","doi":"10.1109/POWERENG.2011.6036541","DOIUrl":null,"url":null,"abstract":"In today's power generation systems, driven by variable-speed prime movers and feeding DC or fixed-frequency grids, the output power of the alternator needs to be rectified. The presence of output rectifier bridges causes a significant distortion of phase currents. This paper investigates the role played by rotor damper circuits in limiting the effects of such distortion. The investigation is extended to the case of multiphase alternator arrangements suitable for supplying a different number of output rectifiers. The study is conducted through tests on an alternator prototype which has been operated with two kinds of rotors, one with and the other without damper circuits. Testing results show that the influence of dampers is significant only in the case of generator three-phase winding and single output bridge.","PeriodicalId":166144,"journal":{"name":"2011 International Conference on Power Engineering, Energy and Electrical Drives","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Experimental evaluation of damper circuit influence on the performance of multiphase synchrnounous generators feeding multiple rectifiers\",\"authors\":\"M. Mezzarobba, Luca Spangaro, A. Tessarolo\",\"doi\":\"10.1109/POWERENG.2011.6036541\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In today's power generation systems, driven by variable-speed prime movers and feeding DC or fixed-frequency grids, the output power of the alternator needs to be rectified. The presence of output rectifier bridges causes a significant distortion of phase currents. This paper investigates the role played by rotor damper circuits in limiting the effects of such distortion. The investigation is extended to the case of multiphase alternator arrangements suitable for supplying a different number of output rectifiers. The study is conducted through tests on an alternator prototype which has been operated with two kinds of rotors, one with and the other without damper circuits. Testing results show that the influence of dampers is significant only in the case of generator three-phase winding and single output bridge.\",\"PeriodicalId\":166144,\"journal\":{\"name\":\"2011 International Conference on Power Engineering, Energy and Electrical Drives\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Power Engineering, Energy and Electrical Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2011.6036541\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2011.6036541","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

在今天的发电系统中,由变速原动机驱动和馈电直流或定频电网,交流发电机的输出功率需要整流。输出整流桥的存在导致相电流的显著畸变。本文研究了转子阻尼电路在限制这种畸变影响方面所起的作用。研究扩展到适用于提供不同数量输出整流器的多相交流发电机布置的情况。本研究是通过在一台交流发电机样机上进行试验来进行的,该样机运行了两种转子,一种是带阻尼电路的,另一种是不带阻尼电路的。试验结果表明,只有在发电机三相绕组和单输出桥的情况下,阻尼器的影响才显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental evaluation of damper circuit influence on the performance of multiphase synchrnounous generators feeding multiple rectifiers
In today's power generation systems, driven by variable-speed prime movers and feeding DC or fixed-frequency grids, the output power of the alternator needs to be rectified. The presence of output rectifier bridges causes a significant distortion of phase currents. This paper investigates the role played by rotor damper circuits in limiting the effects of such distortion. The investigation is extended to the case of multiphase alternator arrangements suitable for supplying a different number of output rectifiers. The study is conducted through tests on an alternator prototype which has been operated with two kinds of rotors, one with and the other without damper circuits. Testing results show that the influence of dampers is significant only in the case of generator three-phase winding and single output bridge.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Low cost DC lines PLC based photovoltaic plants parameters smart monitoring communications and control module Smart meters for distributed filtering of high harmonics in Smart Grid FPGA controller for power converters with integrated oscilloscope and graphical user interface On the square arc voltage waveform model in magnetic discharge lamp studies Interplay of Smart Grids and Intelligent Systems and Control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1