{"title":"[肾外超声及彩色多普勒:肾动脉狭窄]。","authors":"A Rabassini,&nbsp;L Bacarini","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>There is a long term interest in noninvasive Doppler (Duplex Doppler, Color Doppler) methods to screen patients with reno-vascular hypertension resistant to medical therapy. Doppler criteria for the diagnosis of renal artery stenosis in native kidneys vary (peak systolic velocity exceeding 100 cm/sec; RAR (Renal Aortic Ratio) exceeding 3.5; Doppler shift frequency exceeding 6-8 KHz; dampened peripheral waveform; lack of signal in complete occlusion). When the vessels are adequately visualized (about 40% of cases) sensitivity and specificity are quite good (80-90%). In the transplanted kidney Doppler diagnosis of renal artery is easier (diagnostic accuracy about 90%). The diagnostic criteria have been well codified (Doppler shift of 7.5 KHz at an insonating frequency of 3 MHz).</p>","PeriodicalId":8343,"journal":{"name":"Archivio italiano di urologia, nefrologia, andrologia : organo ufficiale dell'Associazione per la ricerca in urologia = Urological, nephrological, and andrological sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1992-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Extrarenal ultrasound and color Doppler: renal artery stenosis].\",\"authors\":\"A Rabassini,&nbsp;L Bacarini\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>There is a long term interest in noninvasive Doppler (Duplex Doppler, Color Doppler) methods to screen patients with reno-vascular hypertension resistant to medical therapy. Doppler criteria for the diagnosis of renal artery stenosis in native kidneys vary (peak systolic velocity exceeding 100 cm/sec; RAR (Renal Aortic Ratio) exceeding 3.5; Doppler shift frequency exceeding 6-8 KHz; dampened peripheral waveform; lack of signal in complete occlusion). When the vessels are adequately visualized (about 40% of cases) sensitivity and specificity are quite good (80-90%). In the transplanted kidney Doppler diagnosis of renal artery is easier (diagnostic accuracy about 90%). The diagnostic criteria have been well codified (Doppler shift of 7.5 KHz at an insonating frequency of 3 MHz).</p>\",\"PeriodicalId\":8343,\"journal\":{\"name\":\"Archivio italiano di urologia, nefrologia, andrologia : organo ufficiale dell'Associazione per la ricerca in urologia = Urological, nephrological, and andrological sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archivio italiano di urologia, nefrologia, andrologia : organo ufficiale dell'Associazione per la ricerca in urologia = Urological, nephrological, and andrological sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivio italiano di urologia, nefrologia, andrologia : organo ufficiale dell'Associazione per la ricerca in urologia = Urological, nephrological, and andrological sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

无创多普勒(双多普勒,彩色多普勒)方法筛查对药物治疗有抗性的肾血管性高血压患者是一个长期的兴趣。原生肾肾动脉狭窄的多普勒诊断标准各不相同(峰值收缩速度超过100cm /sec;肾主动脉比(RAR)超过3.5;多普勒频移频率超过6- 8khz;阻尼周边波形;完全闭塞缺乏信号)。当血管充分显像时(约40%的病例),灵敏度和特异性相当好(80-90%)。在移植肾中,多普勒诊断肾动脉较容易(诊断准确率约90%)。诊断标准已被很好地编纂(超声频率为3mhz时多普勒频移为7.5 KHz)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Extrarenal ultrasound and color Doppler: renal artery stenosis].

There is a long term interest in noninvasive Doppler (Duplex Doppler, Color Doppler) methods to screen patients with reno-vascular hypertension resistant to medical therapy. Doppler criteria for the diagnosis of renal artery stenosis in native kidneys vary (peak systolic velocity exceeding 100 cm/sec; RAR (Renal Aortic Ratio) exceeding 3.5; Doppler shift frequency exceeding 6-8 KHz; dampened peripheral waveform; lack of signal in complete occlusion). When the vessels are adequately visualized (about 40% of cases) sensitivity and specificity are quite good (80-90%). In the transplanted kidney Doppler diagnosis of renal artery is easier (diagnostic accuracy about 90%). The diagnostic criteria have been well codified (Doppler shift of 7.5 KHz at an insonating frequency of 3 MHz).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Ureteritis]. [Structure, physiology and physiopathology of the ureter]. [Ureteral malformations in the adult]. [Ureteritis]. [Primary ureteral neoplasia].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1