谐波六端口雷达系统心肺监测的改进

L. Chioukh, T. Djerafi, D. Deslandes, K. Wu
{"title":"谐波六端口雷达系统心肺监测的改进","authors":"L. Chioukh, T. Djerafi, D. Deslandes, K. Wu","doi":"10.1109/GSMM.2015.7175465","DOIUrl":null,"url":null,"abstract":"A new bio-radar based on a harmonic six-port junction is proposed to improve the performances of monitoring vital sign systems. The amplitude of heart beat compared to the higher harmonics of breathing and the intermodulation product are the main factors influencing the accuracy of the detection. Simulation-based performance demonstrate the advantage of the novel method using the harmonic six-port discriminator for detection. It has been shown that harmonic six-port radar can meet requirements of monitoring vital sign by cancelling breathing harmonic and intermodulation. Experimental results using the proposed platform at 12 GHz and 24 GHz on patient proved the validity and feasibility of cardiopulmonary estimation using harmonic diversity six-port sensor.","PeriodicalId":405509,"journal":{"name":"Global Symposium on Millimeter-Waves (GSMM)","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Improvements of cardiopulmonary monitoring using harmonic six-port radar system\",\"authors\":\"L. Chioukh, T. Djerafi, D. Deslandes, K. Wu\",\"doi\":\"10.1109/GSMM.2015.7175465\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new bio-radar based on a harmonic six-port junction is proposed to improve the performances of monitoring vital sign systems. The amplitude of heart beat compared to the higher harmonics of breathing and the intermodulation product are the main factors influencing the accuracy of the detection. Simulation-based performance demonstrate the advantage of the novel method using the harmonic six-port discriminator for detection. It has been shown that harmonic six-port radar can meet requirements of monitoring vital sign by cancelling breathing harmonic and intermodulation. Experimental results using the proposed platform at 12 GHz and 24 GHz on patient proved the validity and feasibility of cardiopulmonary estimation using harmonic diversity six-port sensor.\",\"PeriodicalId\":405509,\"journal\":{\"name\":\"Global Symposium on Millimeter-Waves (GSMM)\",\"volume\":\"78 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Global Symposium on Millimeter-Waves (GSMM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GSMM.2015.7175465\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Symposium on Millimeter-Waves (GSMM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GSMM.2015.7175465","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

为了提高生命体征监测系统的性能,提出了一种基于谐波六端口结的新型生物雷达。影响检测精度的主要因素是心跳相对于呼吸高次谐波的幅值和互调积。基于仿真的性能验证了采用谐波六端口鉴别器进行检测的新方法的优越性。研究表明,谐波六口雷达通过消除呼吸谐波和互调,可以满足生命体征监测的要求。实验结果表明,该平台在12 GHz和24 GHz频段对患者进行心肺功能估计的有效性和可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Improvements of cardiopulmonary monitoring using harmonic six-port radar system
A new bio-radar based on a harmonic six-port junction is proposed to improve the performances of monitoring vital sign systems. The amplitude of heart beat compared to the higher harmonics of breathing and the intermodulation product are the main factors influencing the accuracy of the detection. Simulation-based performance demonstrate the advantage of the novel method using the harmonic six-port discriminator for detection. It has been shown that harmonic six-port radar can meet requirements of monitoring vital sign by cancelling breathing harmonic and intermodulation. Experimental results using the proposed platform at 12 GHz and 24 GHz on patient proved the validity and feasibility of cardiopulmonary estimation using harmonic diversity six-port sensor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
V-band six-port quadrature demodulator : Error Vector Magnitude analysis Design and optimization of a shaped-beam ka-band substrate integrated waveguide antenna array Millimeter wave orthogonally polarized substrate integrated waveguide slot antenna arrays Development of a wideband double-ridged pyramidal horn for a 22∼129 GHz band phase calibration system Gain enhancement of SIW-integrated patch antenna for emerging millimeter wave systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1