{"title":"JT-60U型导流器底板的设计与制造","authors":"K. Ioki, K. Namiki, Y. Suzuki, T. Shimomura, H. Kaguchi, K. Ue, T. Ando, M. Yamamoto, Y. Neyatani, H. Ninomiya, M. Matsukawa, H. Horiike","doi":"10.1109/FUSION.1991.218691","DOIUrl":null,"url":null,"abstract":"The divertor plates have been designed and fabricated for JT-60U (JAERI Tokamak-60 upgrade). The bottom part of the vacuum vessel is fully covered with the divertor plates. The divertor plates are subject to a heat load of 20 MW/m/sup 2/ for 5 s in a 30-mm-wide band. The divertor plates consist of 125 base plates with cooling tubes. Each divertor base plate is held on the vessel wall by a fixed support and sliding supports in order to accommodate thermal expansion differences and withstand magnetic forces. The divertor base plates have been designed to take up as little space as possible in order to gain larger plasma volume. High dimensional and positional accuracy was obtained successfully in the divertor base plates fabricated and installed into the JT-60U vacuum vessel. The achieved accuracy of the base-plate height was within 0.6 mm for neighboring base plates.<<ETX>>","PeriodicalId":318951,"journal":{"name":"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Design and fabrication of divertor base-plate for JT-60U\",\"authors\":\"K. Ioki, K. Namiki, Y. Suzuki, T. Shimomura, H. Kaguchi, K. Ue, T. Ando, M. Yamamoto, Y. Neyatani, H. Ninomiya, M. Matsukawa, H. Horiike\",\"doi\":\"10.1109/FUSION.1991.218691\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The divertor plates have been designed and fabricated for JT-60U (JAERI Tokamak-60 upgrade). The bottom part of the vacuum vessel is fully covered with the divertor plates. The divertor plates are subject to a heat load of 20 MW/m/sup 2/ for 5 s in a 30-mm-wide band. The divertor plates consist of 125 base plates with cooling tubes. Each divertor base plate is held on the vessel wall by a fixed support and sliding supports in order to accommodate thermal expansion differences and withstand magnetic forces. The divertor base plates have been designed to take up as little space as possible in order to gain larger plasma volume. High dimensional and positional accuracy was obtained successfully in the divertor base plates fabricated and installed into the JT-60U vacuum vessel. The achieved accuracy of the base-plate height was within 0.6 mm for neighboring base plates.<<ETX>>\",\"PeriodicalId\":318951,\"journal\":{\"name\":\"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FUSION.1991.218691\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FUSION.1991.218691","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

导流板已经为JT-60U (JAERI托卡马克-60升级)设计和制造。真空容器的底部完全覆盖有分流板。导流板在30mm宽的波段内承受20 MW/m/sup /的热负荷5 s。导流板由125个带冷却管的底板组成。每个导流器底板通过固定支架和滑动支架固定在容器壁上,以适应热膨胀差异并承受磁力。为了获得更大的等离子体体积,分流器基板被设计成占用尽可能少的空间。制造并安装在JT-60U真空容器中的导流器底板,成功地获得了较高的尺寸精度和位置精度。相邻底板的底板高度精度在0.6 mm以内
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and fabrication of divertor base-plate for JT-60U
The divertor plates have been designed and fabricated for JT-60U (JAERI Tokamak-60 upgrade). The bottom part of the vacuum vessel is fully covered with the divertor plates. The divertor plates are subject to a heat load of 20 MW/m/sup 2/ for 5 s in a 30-mm-wide band. The divertor plates consist of 125 base plates with cooling tubes. Each divertor base plate is held on the vessel wall by a fixed support and sliding supports in order to accommodate thermal expansion differences and withstand magnetic forces. The divertor base plates have been designed to take up as little space as possible in order to gain larger plasma volume. High dimensional and positional accuracy was obtained successfully in the divertor base plates fabricated and installed into the JT-60U vacuum vessel. The achieved accuracy of the base-plate height was within 0.6 mm for neighboring base plates.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design of a coil to correct magnetic field errors on the DIII-D tokamak The charge exchange recombination diagnostic system on the DIII-D tokamak Software upgrade for the DIII-D neutral beam control systems Timing system for neutral beam injection on the DIII-D tokamak DIII-D radiation shielding procedures and experiences
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1