S. Livens, J. Blommaert, D. Nuyts, A. Sima, P. Baeck, B. Delauré
{"title":"cosi高光谱RPAS相机的辐射定标","authors":"S. Livens, J. Blommaert, D. Nuyts, A. Sima, P. Baeck, B. Delauré","doi":"10.1109/WHISPERS.2016.8071688","DOIUrl":null,"url":null,"abstract":"The COSI hyperspectral imaging system, suitable for small RPAS, is able to produce high resolution hyperspectral data products. By extensive inflight testing, we have identified the main challenges for achieving reliable high quality results. Based on these insights, we propose a refined radiometric calibration strategy. It uses a set of three reference targets, two grey and one colored target, which are to be measured inflight. We present on-ground measurements of the targets with COSI, as in flight measurements, demonstrating the merits of the approach are still ongoing.","PeriodicalId":369281,"journal":{"name":"2016 8th Workshop on Hyperspectral Image and Signal Processing: Evolution in Remote Sensing (WHISPERS)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Radiometric calibration of the cosi hyperspectral RPAS camera\",\"authors\":\"S. Livens, J. Blommaert, D. Nuyts, A. Sima, P. Baeck, B. Delauré\",\"doi\":\"10.1109/WHISPERS.2016.8071688\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The COSI hyperspectral imaging system, suitable for small RPAS, is able to produce high resolution hyperspectral data products. By extensive inflight testing, we have identified the main challenges for achieving reliable high quality results. Based on these insights, we propose a refined radiometric calibration strategy. It uses a set of three reference targets, two grey and one colored target, which are to be measured inflight. We present on-ground measurements of the targets with COSI, as in flight measurements, demonstrating the merits of the approach are still ongoing.\",\"PeriodicalId\":369281,\"journal\":{\"name\":\"2016 8th Workshop on Hyperspectral Image and Signal Processing: Evolution in Remote Sensing (WHISPERS)\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 8th Workshop on Hyperspectral Image and Signal Processing: Evolution in Remote Sensing (WHISPERS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WHISPERS.2016.8071688\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 8th Workshop on Hyperspectral Image and Signal Processing: Evolution in Remote Sensing (WHISPERS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WHISPERS.2016.8071688","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Radiometric calibration of the cosi hyperspectral RPAS camera
The COSI hyperspectral imaging system, suitable for small RPAS, is able to produce high resolution hyperspectral data products. By extensive inflight testing, we have identified the main challenges for achieving reliable high quality results. Based on these insights, we propose a refined radiometric calibration strategy. It uses a set of three reference targets, two grey and one colored target, which are to be measured inflight. We present on-ground measurements of the targets with COSI, as in flight measurements, demonstrating the merits of the approach are still ongoing.