基于自适应三角测量原理的中压电网故障定位

Marek Höger, P. Braciník, J. Altus, A. Otcenásová
{"title":"基于自适应三角测量原理的中压电网故障定位","authors":"Marek Höger, P. Braciník, J. Altus, A. Otcenásová","doi":"10.1109/ISGTEUROPE.2010.5638873","DOIUrl":null,"url":null,"abstract":"This paper describes a new fault location method for medium voltage networks consisting of power distribution lines with tree topology. The method is based on the adaptation of triangulation principle. It uses the detection of undervoltage wave propagation as a source of information for fault location calculation. The paper gives short description of triangulation principle adaptation, needed input data as well as factors influencing calculation accuracy. Calculation algorithm is then described in more details and its principle is explained through simplified short example of fault location calculation. Proposed method utilizes Smart Grid concept, because its functionality depends on data exchange between measuring points placed in distribution power lines and control centre, where the fault location calculation is done.","PeriodicalId":267185,"journal":{"name":"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Fault location in medium voltage networks by the help of adapted triangulation principle\",\"authors\":\"Marek Höger, P. Braciník, J. Altus, A. Otcenásová\",\"doi\":\"10.1109/ISGTEUROPE.2010.5638873\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a new fault location method for medium voltage networks consisting of power distribution lines with tree topology. The method is based on the adaptation of triangulation principle. It uses the detection of undervoltage wave propagation as a source of information for fault location calculation. The paper gives short description of triangulation principle adaptation, needed input data as well as factors influencing calculation accuracy. Calculation algorithm is then described in more details and its principle is explained through simplified short example of fault location calculation. Proposed method utilizes Smart Grid concept, because its functionality depends on data exchange between measuring points placed in distribution power lines and control centre, where the fault location calculation is done.\",\"PeriodicalId\":267185,\"journal\":{\"name\":\"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEUROPE.2010.5638873\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEUROPE.2010.5638873","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文提出了一种树形拓扑的中压配电网故障定位新方法。该方法基于三角剖分原理的自适应。它利用欠压波传播的检测作为故障定位计算的信息来源。本文简要介绍了三角测量原理的适应、需要输入的数据以及影响计算精度的因素。然后详细介绍了计算算法,并通过简化的故障定位计算实例说明了其原理。该方法利用智能电网的概念,其功能依赖于配电线路测点与控制中心之间的数据交换,控制中心进行故障定位计算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fault location in medium voltage networks by the help of adapted triangulation principle
This paper describes a new fault location method for medium voltage networks consisting of power distribution lines with tree topology. The method is based on the adaptation of triangulation principle. It uses the detection of undervoltage wave propagation as a source of information for fault location calculation. The paper gives short description of triangulation principle adaptation, needed input data as well as factors influencing calculation accuracy. Calculation algorithm is then described in more details and its principle is explained through simplified short example of fault location calculation. Proposed method utilizes Smart Grid concept, because its functionality depends on data exchange between measuring points placed in distribution power lines and control centre, where the fault location calculation is done.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
IEEE DEIS and Smart Grid: How to fit in Benchmarking set for domestic smart grid management Smart distribution protection using current-only directional overcurrent relay Operating conditions forecasting for monitoring and control of electric power systems Active distribution network — Demonstration project ADINE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1