用卷积法验证脉冲电压测量系统的精度

P. Yutthagowith, N. Pattanadech, A. Kunakorn, S. Phoomvuthisarn
{"title":"用卷积法验证脉冲电压测量系统的精度","authors":"P. Yutthagowith, N. Pattanadech, A. Kunakorn, S. Phoomvuthisarn","doi":"10.1109/IPEC.2005.206930","DOIUrl":null,"url":null,"abstract":"This paper presents verification of high voltage measuring systems by time convolutions between standard testing waveforms and unit step responses of the measuring systems. The waveforms under investigations are full lightning impulse voltage waveforms, tail-chopped lightning impulse voltage waveforms, front-chopped lightning impulse voltage waveforms and steep-front voltage waveforms according to IEC standards 60060-2 and 61211. This paper considers four different types of the measuring systems. The results show that this technique is applicable, and should be a useful method for impulse voltage measurements in a standard high voltage","PeriodicalId":164802,"journal":{"name":"2005 International Power Engineering Conference","volume":"2015 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Accuracy verification of impulse voltage measuring systems by convolution methods\",\"authors\":\"P. Yutthagowith, N. Pattanadech, A. Kunakorn, S. Phoomvuthisarn\",\"doi\":\"10.1109/IPEC.2005.206930\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents verification of high voltage measuring systems by time convolutions between standard testing waveforms and unit step responses of the measuring systems. The waveforms under investigations are full lightning impulse voltage waveforms, tail-chopped lightning impulse voltage waveforms, front-chopped lightning impulse voltage waveforms and steep-front voltage waveforms according to IEC standards 60060-2 and 61211. This paper considers four different types of the measuring systems. The results show that this technique is applicable, and should be a useful method for impulse voltage measurements in a standard high voltage\",\"PeriodicalId\":164802,\"journal\":{\"name\":\"2005 International Power Engineering Conference\",\"volume\":\"2015 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 International Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEC.2005.206930\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEC.2005.206930","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了用标准测试波形与测量系统的单位阶跃响应之间的时间卷积来验证高压测量系统。根据IEC标准60060-2和61211,所研究的波形有全雷电冲击电压波形、尾斩雷电冲击电压波形、前斩雷电冲击电压波形和陡前斩雷电冲击电压波形。本文考虑了四种不同类型的测量系统。结果表明,该方法是可行的,可作为标准高压脉冲电压测量的一种有效方法
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accuracy verification of impulse voltage measuring systems by convolution methods
This paper presents verification of high voltage measuring systems by time convolutions between standard testing waveforms and unit step responses of the measuring systems. The waveforms under investigations are full lightning impulse voltage waveforms, tail-chopped lightning impulse voltage waveforms, front-chopped lightning impulse voltage waveforms and steep-front voltage waveforms according to IEC standards 60060-2 and 61211. This paper considers four different types of the measuring systems. The results show that this technique is applicable, and should be a useful method for impulse voltage measurements in a standard high voltage
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The application of association rule mining in power system restoration The influence of model mismatch to power system calculation, part II: on the stability calculation Optimal participation of a microgrid to the energy market with an intelligent EMS An account of a modified lightning protection system for power stations An improved usage allocation method for deregulated transmission systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1