C. Koch-Ciobotaru, R. Boraci, O. Proștean, I. Szeidert
{"title":"基于需求响应的微电网电压控制","authors":"C. Koch-Ciobotaru, R. Boraci, O. Proștean, I. Szeidert","doi":"10.1109/SACI.2013.6608974","DOIUrl":null,"url":null,"abstract":"This paper presents comparisons of two controllers implemented at the level of a household heating system for voltage control at the point of coupling with the distribution grid. The voltage is maintained between safety limits using demand response, the electric heaters being used to follow two objectives: to control the inside temperature as well as to control the consumption and, thus, the voltage. Study cases and simulations were conducted in Power Factory on a modeled microgrid structure.","PeriodicalId":304729,"journal":{"name":"2013 IEEE 8th International Symposium on Applied Computational Intelligence and Informatics (SACI)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Voltage control in a microgrid using demand response\",\"authors\":\"C. Koch-Ciobotaru, R. Boraci, O. Proștean, I. Szeidert\",\"doi\":\"10.1109/SACI.2013.6608974\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents comparisons of two controllers implemented at the level of a household heating system for voltage control at the point of coupling with the distribution grid. The voltage is maintained between safety limits using demand response, the electric heaters being used to follow two objectives: to control the inside temperature as well as to control the consumption and, thus, the voltage. Study cases and simulations were conducted in Power Factory on a modeled microgrid structure.\",\"PeriodicalId\":304729,\"journal\":{\"name\":\"2013 IEEE 8th International Symposium on Applied Computational Intelligence and Informatics (SACI)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE 8th International Symposium on Applied Computational Intelligence and Informatics (SACI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SACI.2013.6608974\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 8th International Symposium on Applied Computational Intelligence and Informatics (SACI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SACI.2013.6608974","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Voltage control in a microgrid using demand response
This paper presents comparisons of two controllers implemented at the level of a household heating system for voltage control at the point of coupling with the distribution grid. The voltage is maintained between safety limits using demand response, the electric heaters being used to follow two objectives: to control the inside temperature as well as to control the consumption and, thus, the voltage. Study cases and simulations were conducted in Power Factory on a modeled microgrid structure.