G. Cho, Min-Sung Kim, Dong-Hyun Kim, Chul-Hwan Kim
{"title":"交流电力铁路馈电系统百分率差动继电器的建模与验证研究","authors":"G. Cho, Min-Sung Kim, Dong-Hyun Kim, Chul-Hwan Kim","doi":"10.1109/TENCON.2018.8650244","DOIUrl":null,"url":null,"abstract":"In general, a Scott-transformer is used to supply the single-phase power for the Korean AC electric railway feeding system. In particular, the Korean Autotransformer feeding system has a different configuration compared to those of other countries, therefore, it has certain distinctive characteristics. In addition, a percentage differential relay is widely and globally utilized for protecting the transformers. However, detailed modeling and simulation for the relay protecting the Korean AC electric railway feeding system is not performed enough. Thus, in this paper, we modeled and verified the percentage differential relay for AC electric railway feeding system by using PSCAD/EMTDC. A simple method to prevent malfunction due to a saturation of the current transformer is suggested as well.","PeriodicalId":132900,"journal":{"name":"TENCON 2018 - 2018 IEEE Region 10 Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Study on Modeling and Verification of the Percentage Differential Relay for the Protection of AC Electric Railway Feeding System\",\"authors\":\"G. Cho, Min-Sung Kim, Dong-Hyun Kim, Chul-Hwan Kim\",\"doi\":\"10.1109/TENCON.2018.8650244\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In general, a Scott-transformer is used to supply the single-phase power for the Korean AC electric railway feeding system. In particular, the Korean Autotransformer feeding system has a different configuration compared to those of other countries, therefore, it has certain distinctive characteristics. In addition, a percentage differential relay is widely and globally utilized for protecting the transformers. However, detailed modeling and simulation for the relay protecting the Korean AC electric railway feeding system is not performed enough. Thus, in this paper, we modeled and verified the percentage differential relay for AC electric railway feeding system by using PSCAD/EMTDC. A simple method to prevent malfunction due to a saturation of the current transformer is suggested as well.\",\"PeriodicalId\":132900,\"journal\":{\"name\":\"TENCON 2018 - 2018 IEEE Region 10 Conference\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TENCON 2018 - 2018 IEEE Region 10 Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TENCON.2018.8650244\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TENCON 2018 - 2018 IEEE Region 10 Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENCON.2018.8650244","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Study on Modeling and Verification of the Percentage Differential Relay for the Protection of AC Electric Railway Feeding System
In general, a Scott-transformer is used to supply the single-phase power for the Korean AC electric railway feeding system. In particular, the Korean Autotransformer feeding system has a different configuration compared to those of other countries, therefore, it has certain distinctive characteristics. In addition, a percentage differential relay is widely and globally utilized for protecting the transformers. However, detailed modeling and simulation for the relay protecting the Korean AC electric railway feeding system is not performed enough. Thus, in this paper, we modeled and verified the percentage differential relay for AC electric railway feeding system by using PSCAD/EMTDC. A simple method to prevent malfunction due to a saturation of the current transformer is suggested as well.