JPEG 2000压缩在医学数据库图像数据中的应用

G. Anastassopoulos, A. D. Tsalkidis, I. Stephanakis, G. Mandellos, K. Simopoulos
{"title":"JPEG 2000压缩在医学数据库图像数据中的应用","authors":"G. Anastassopoulos, A. D. Tsalkidis, I. Stephanakis, G. Mandellos, K. Simopoulos","doi":"10.1109/ICDSP.2002.1028146","DOIUrl":null,"url":null,"abstract":"A medical database has been developed in the pediatric clinic of the University Hospital of Alexandroupolis in order to organize and manipulate all clinical information in digital form. A compression technique that trades between the amount of data stored/transmitted and the quality of the image may be used in order to reduce the amount of stored/transmitted image data. A comparative evaluation of JPEG and JPEG2000 compression standards by means of both subjective and objective criteria was performed in order to select the appropriate compression technique for the database medical images. JPEG 2000 proves to be an ideal file format for the pediatric DB application, since it compresses the image data up to 98.4% without any loss in the diagnostic information of the image.","PeriodicalId":351073,"journal":{"name":"2002 14th International Conference on Digital Signal Processing Proceedings. DSP 2002 (Cat. No.02TH8628)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Application of JPEG 2000 compression in medical database image data\",\"authors\":\"G. Anastassopoulos, A. D. Tsalkidis, I. Stephanakis, G. Mandellos, K. Simopoulos\",\"doi\":\"10.1109/ICDSP.2002.1028146\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A medical database has been developed in the pediatric clinic of the University Hospital of Alexandroupolis in order to organize and manipulate all clinical information in digital form. A compression technique that trades between the amount of data stored/transmitted and the quality of the image may be used in order to reduce the amount of stored/transmitted image data. A comparative evaluation of JPEG and JPEG2000 compression standards by means of both subjective and objective criteria was performed in order to select the appropriate compression technique for the database medical images. JPEG 2000 proves to be an ideal file format for the pediatric DB application, since it compresses the image data up to 98.4% without any loss in the diagnostic information of the image.\",\"PeriodicalId\":351073,\"journal\":{\"name\":\"2002 14th International Conference on Digital Signal Processing Proceedings. DSP 2002 (Cat. No.02TH8628)\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2002 14th International Conference on Digital Signal Processing Proceedings. DSP 2002 (Cat. No.02TH8628)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICDSP.2002.1028146\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 14th International Conference on Digital Signal Processing Proceedings. DSP 2002 (Cat. No.02TH8628)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDSP.2002.1028146","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

在亚历山德鲁波利斯大学医院的儿科诊所建立了一个医疗数据库,以便以数字形式组织和处理所有临床信息。为了减少存储/传输的图像数据的量,可以使用在存储/传输的数据量和图像质量之间进行交换的压缩技术。从主观和客观两个方面对JPEG和JPEG2000压缩标准进行了比较评价,以选择适合数据库医学图像的压缩技术。JPEG 2000被证明是儿科DB应用程序的理想文件格式,因为它将图像数据压缩到98.4%,而不会丢失图像的诊断信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Application of JPEG 2000 compression in medical database image data
A medical database has been developed in the pediatric clinic of the University Hospital of Alexandroupolis in order to organize and manipulate all clinical information in digital form. A compression technique that trades between the amount of data stored/transmitted and the quality of the image may be used in order to reduce the amount of stored/transmitted image data. A comparative evaluation of JPEG and JPEG2000 compression standards by means of both subjective and objective criteria was performed in order to select the appropriate compression technique for the database medical images. JPEG 2000 proves to be an ideal file format for the pediatric DB application, since it compresses the image data up to 98.4% without any loss in the diagnostic information of the image.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
H/sub /spl infin// bounded optimal updating - down-dating algorithm A systematic approach to seizure prediction using genetic and classifier based feature selection A prognostic-classification system based on a probabilistic NN for predicting urine bladder cancer recurrence Implementation of real-time AMDF pitch-detection for voice gender normalisation Fourier filtering of continuous global surfaces
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1