超高分辨率毫米波成像:一种新的有前途的皮肤癌成像方式

Amir Mirbeik-Sabzevari, Negar Tavassolian, R. Ashinoff
{"title":"超高分辨率毫米波成像:一种新的有前途的皮肤癌成像方式","authors":"Amir Mirbeik-Sabzevari, Negar Tavassolian, R. Ashinoff","doi":"10.1109/BIOCAS.2018.8584772","DOIUrl":null,"url":null,"abstract":"The goal of this study is to investigate the feasibility of using millimeter-wave imaging as a new medical imaging modality for the detection of skin cancer at early stages. In a recent large-scale study, the authors have demonstrated that statistically considerable contrasts exist between the millimeter-wave dielectric properties of normal skin and skin cancer tissues. In this work, an imaging system with a record-wide bandwidth of 98 GHz was developed using the synthetic ultra-wideband millimeterwave imaging approach, a new ultra-high-resolution imaging technique recently developed by the authors. Ex-vivo imaging experiments were conducted on two freshly-excised malignant skin tissues obtained from skin cancer patients having undergone Mohs micrographic surgeries at Hackensack University Medical Center. A programmable measurement platform was designed to automatically scan the tissues across a rectangular aperture plane. Furthermore, a novel frequency-domain imaging algorithm was developed to process the recorded signals and generate an image of the cancerous tissue. The obtained images correctly identified the tumor locations as verified by Mohs histological evaluations.","PeriodicalId":259162,"journal":{"name":"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Ultra-High-Resolution Millimeter-Wave Imaging: A New Promising Skin Cancer Imaging Modality\",\"authors\":\"Amir Mirbeik-Sabzevari, Negar Tavassolian, R. Ashinoff\",\"doi\":\"10.1109/BIOCAS.2018.8584772\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The goal of this study is to investigate the feasibility of using millimeter-wave imaging as a new medical imaging modality for the detection of skin cancer at early stages. In a recent large-scale study, the authors have demonstrated that statistically considerable contrasts exist between the millimeter-wave dielectric properties of normal skin and skin cancer tissues. In this work, an imaging system with a record-wide bandwidth of 98 GHz was developed using the synthetic ultra-wideband millimeterwave imaging approach, a new ultra-high-resolution imaging technique recently developed by the authors. Ex-vivo imaging experiments were conducted on two freshly-excised malignant skin tissues obtained from skin cancer patients having undergone Mohs micrographic surgeries at Hackensack University Medical Center. A programmable measurement platform was designed to automatically scan the tissues across a rectangular aperture plane. Furthermore, a novel frequency-domain imaging algorithm was developed to process the recorded signals and generate an image of the cancerous tissue. The obtained images correctly identified the tumor locations as verified by Mohs histological evaluations.\",\"PeriodicalId\":259162,\"journal\":{\"name\":\"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2018.8584772\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2018.8584772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本研究的目的是探讨毫米波成像作为一种新的医学成像方式在早期检测皮肤癌的可行性。在最近的一项大规模研究中,作者已经证明,正常皮肤和皮肤癌组织的毫米波介电特性之间存在统计学上相当大的差异。在这项工作中,利用作者最近开发的一种新的超高分辨率成像技术——合成超宽带毫米波成像方法,开发了一个记录带宽为98 GHz的成像系统。对在哈肯萨克大学医学中心接受莫氏显微摄影手术的皮肤癌患者新近切除的两个恶性皮肤组织进行了离体成像实验。设计了一个可编程的测量平台,通过矩形孔径平面对组织进行自动扫描。此外,开发了一种新的频域成像算法来处理记录的信号并生成癌组织的图像。获得的图像正确地识别肿瘤位置,并通过Mohs组织学评估验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultra-High-Resolution Millimeter-Wave Imaging: A New Promising Skin Cancer Imaging Modality
The goal of this study is to investigate the feasibility of using millimeter-wave imaging as a new medical imaging modality for the detection of skin cancer at early stages. In a recent large-scale study, the authors have demonstrated that statistically considerable contrasts exist between the millimeter-wave dielectric properties of normal skin and skin cancer tissues. In this work, an imaging system with a record-wide bandwidth of 98 GHz was developed using the synthetic ultra-wideband millimeterwave imaging approach, a new ultra-high-resolution imaging technique recently developed by the authors. Ex-vivo imaging experiments were conducted on two freshly-excised malignant skin tissues obtained from skin cancer patients having undergone Mohs micrographic surgeries at Hackensack University Medical Center. A programmable measurement platform was designed to automatically scan the tissues across a rectangular aperture plane. Furthermore, a novel frequency-domain imaging algorithm was developed to process the recorded signals and generate an image of the cancerous tissue. The obtained images correctly identified the tumor locations as verified by Mohs histological evaluations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Smart Prosthesis System: Continuous Automatic Prosthesis Fitting Adjustment and Real-time Stress Visualization Framework of Applying Independent Component Analysis After Compressed Sensing for Electroencephalogram Signals Live Demonstration: A Bluetooth Low Energy (BLE)-enabled Wireless Link for Bidirectional Communications with a Neural Microsystem The Spectral Calibration of Swept-Source Optical Coherence Tomography Systems Using Unscented Kalman Filter An Ultra-Wideband-Inspired System-on-Chip for an Optical Bidirectional Transcutaneous Biotelemetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1