S. L. Katz, J. Likar, Chi H. Pham, Dakai Chen, Natnael J. Ahmed
{"title":"重离子单事件效应(SEE)对OPA128静电计级运算放大器的影响","authors":"S. L. Katz, J. Likar, Chi H. Pham, Dakai Chen, Natnael J. Ahmed","doi":"10.1109/NSREC45046.2021.9679341","DOIUrl":null,"url":null,"abstract":"The OPA128 is an electrometer grade operational amplifier with femtoamp bias currents [1], potentially offering better performance than other rad-hard precision op amps available today [2], [3], [4], [5], [6]. Heavy ion testing to qualify it for use on the Europa Clipper mission uncovered a destructive failure not noted in prior testing [7], [8], [9], precipitating additional testing to explore the failure and determine the part's viability for spaceflight. Testing yielded a proposed safe operating area (SOA). Non-destructive transient events were also observed and characterized for multiple applications.","PeriodicalId":340911,"journal":{"name":"2021 IEEE Nuclear and Space Radiation Effects Conference (NSREC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Heavy Ion Single Event Effects (SEE) results for OPA128 Electrometer Grade Operational Amplifier\",\"authors\":\"S. L. Katz, J. Likar, Chi H. Pham, Dakai Chen, Natnael J. Ahmed\",\"doi\":\"10.1109/NSREC45046.2021.9679341\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The OPA128 is an electrometer grade operational amplifier with femtoamp bias currents [1], potentially offering better performance than other rad-hard precision op amps available today [2], [3], [4], [5], [6]. Heavy ion testing to qualify it for use on the Europa Clipper mission uncovered a destructive failure not noted in prior testing [7], [8], [9], precipitating additional testing to explore the failure and determine the part's viability for spaceflight. Testing yielded a proposed safe operating area (SOA). Non-destructive transient events were also observed and characterized for multiple applications.\",\"PeriodicalId\":340911,\"journal\":{\"name\":\"2021 IEEE Nuclear and Space Radiation Effects Conference (NSREC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE Nuclear and Space Radiation Effects Conference (NSREC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSREC45046.2021.9679341\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Nuclear and Space Radiation Effects Conference (NSREC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSREC45046.2021.9679341","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Heavy Ion Single Event Effects (SEE) results for OPA128 Electrometer Grade Operational Amplifier
The OPA128 is an electrometer grade operational amplifier with femtoamp bias currents [1], potentially offering better performance than other rad-hard precision op amps available today [2], [3], [4], [5], [6]. Heavy ion testing to qualify it for use on the Europa Clipper mission uncovered a destructive failure not noted in prior testing [7], [8], [9], precipitating additional testing to explore the failure and determine the part's viability for spaceflight. Testing yielded a proposed safe operating area (SOA). Non-destructive transient events were also observed and characterized for multiple applications.