Dung Trung Pham, Anh Tuan Nhu Nguyen, Cuong Xuan Cao, Tinh Duc Le, C. Le, Cuong Sy Ngo
{"title":"地面激光扫描器直接地理参考的切除方法","authors":"Dung Trung Pham, Anh Tuan Nhu Nguyen, Cuong Xuan Cao, Tinh Duc Le, C. Le, Cuong Sy Ngo","doi":"10.46326/jmes.2022.63(3).07","DOIUrl":null,"url":null,"abstract":"Recently, the direct georeferencing method has been increasingly used in Terrestrial Laser Scanner (TLS). This method has the benefit of saving time, but the low accuracy is a great difficulty to use. This paper proposed a possible approach for direct georeferencing with high accuracy using the resection method. Thanks to new series of TLS combined with a total station called the total station scanner, the resection method can be applied to overcome the problem. However, the assessment of the resection method on the quality of the point cloud is lacking up to now. In this paper, the influence of components of error sources in the resection method on the total error of the point cloud is analyzed. In the experiment, a Topcon GTL-1000 total station scanner was employed. A ground control network and checkered targets were established by a Leica TS06 plus total station. The experimental results verify that the total error of point cloud entirely agrees with the theory about georeferencing using the resection method. In addition, the distance and incidence angle from the scanner to the measured object are the main factors that considerably influence the accuracy of the point cloud. The relationship between these factors and the accuracy of the point cloud is non-linear measured by a coefficient of determination (R2>0.7). Using the resection method, the coordinates of the scan station can obtain at a millimeter level in accuracy. As a result, the resection method is one of the most suitable methods that can be applied for georeferencing in TLS. The high accuracy and saving time for TLS data post-processing in the office are enormous benefits of this method.","PeriodicalId":170167,"journal":{"name":"Journal of Mining and Earth Sciences","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Resection method for direct georeferencing in Terrestrial Laser Scanner\",\"authors\":\"Dung Trung Pham, Anh Tuan Nhu Nguyen, Cuong Xuan Cao, Tinh Duc Le, C. Le, Cuong Sy Ngo\",\"doi\":\"10.46326/jmes.2022.63(3).07\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, the direct georeferencing method has been increasingly used in Terrestrial Laser Scanner (TLS). This method has the benefit of saving time, but the low accuracy is a great difficulty to use. This paper proposed a possible approach for direct georeferencing with high accuracy using the resection method. Thanks to new series of TLS combined with a total station called the total station scanner, the resection method can be applied to overcome the problem. However, the assessment of the resection method on the quality of the point cloud is lacking up to now. In this paper, the influence of components of error sources in the resection method on the total error of the point cloud is analyzed. In the experiment, a Topcon GTL-1000 total station scanner was employed. A ground control network and checkered targets were established by a Leica TS06 plus total station. The experimental results verify that the total error of point cloud entirely agrees with the theory about georeferencing using the resection method. In addition, the distance and incidence angle from the scanner to the measured object are the main factors that considerably influence the accuracy of the point cloud. The relationship between these factors and the accuracy of the point cloud is non-linear measured by a coefficient of determination (R2>0.7). Using the resection method, the coordinates of the scan station can obtain at a millimeter level in accuracy. As a result, the resection method is one of the most suitable methods that can be applied for georeferencing in TLS. The high accuracy and saving time for TLS data post-processing in the office are enormous benefits of this method.\",\"PeriodicalId\":170167,\"journal\":{\"name\":\"Journal of Mining and Earth Sciences\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mining and Earth Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46326/jmes.2022.63(3).07\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mining and Earth Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46326/jmes.2022.63(3).07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

近年来,直接地理参考方法在地面激光扫描器(TLS)中的应用越来越广泛。该方法具有节省时间的优点,但精度低,使用难度大。本文提出了一种利用切离法进行高精度直接地理参考的可能方法。由于新系列的TLS与称为全站仪扫描仪的全站仪相结合,可以应用切除方法来克服这个问题。然而,目前对点云质量的评价方法还比较缺乏。本文分析了交会方法中误差源分量对点云总误差的影响。实验采用Topcon GTL-1000全站仪。地面控制网和方格目标由徕卡TS06加全站仪建立。实验结果验证了点云的总误差完全符合用切分法进行地理参考的理论。此外,扫描仪到被测物体的距离和入射角是影响点云精度的主要因素。这些因素与点云精度之间的关系是非线性的,通过决定系数(R2>0.7)来测量。采用该方法,扫描站的坐标精度可达到毫米级。因此,切除法是TLS中最适合用于地理参考的方法之一。该方法的巨大优点是对TLS数据的后处理精度高、节省时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Resection method for direct georeferencing in Terrestrial Laser Scanner
Recently, the direct georeferencing method has been increasingly used in Terrestrial Laser Scanner (TLS). This method has the benefit of saving time, but the low accuracy is a great difficulty to use. This paper proposed a possible approach for direct georeferencing with high accuracy using the resection method. Thanks to new series of TLS combined with a total station called the total station scanner, the resection method can be applied to overcome the problem. However, the assessment of the resection method on the quality of the point cloud is lacking up to now. In this paper, the influence of components of error sources in the resection method on the total error of the point cloud is analyzed. In the experiment, a Topcon GTL-1000 total station scanner was employed. A ground control network and checkered targets were established by a Leica TS06 plus total station. The experimental results verify that the total error of point cloud entirely agrees with the theory about georeferencing using the resection method. In addition, the distance and incidence angle from the scanner to the measured object are the main factors that considerably influence the accuracy of the point cloud. The relationship between these factors and the accuracy of the point cloud is non-linear measured by a coefficient of determination (R2>0.7). Using the resection method, the coordinates of the scan station can obtain at a millimeter level in accuracy. As a result, the resection method is one of the most suitable methods that can be applied for georeferencing in TLS. The high accuracy and saving time for TLS data post-processing in the office are enormous benefits of this method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
ESP Application for Oil Production in Naturally Fractured Granitic Basement Reservoir Comparison analytical hierarchy process (AHP) and frequency ratio (FR) method in assessment of landslide susceptibility. A case study in Van Yen district, Yen Bai province Deep geological structure of An Chau trough base on new study data Assessment of liquefaction potential of sand distributed in the 1 District, Ho Chi Minh city Geotechnical zoning in Hai Duong province for construction planning
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1