J Wojnar, A Bochenek, A M Wnuk-Wojnar, Z Religa, J Hołowiecki
{"title":"自体氧合体外循环技术的血液相容性:对血小板功能和同源血需氧量的影响。","authors":"J Wojnar, A Bochenek, A M Wnuk-Wojnar, Z Religa, J Hołowiecki","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Forty male patients: group A-autooxygenation and group B-bubble oxygenator used in extracorporeal circulation (ECC) were studied to evaluate the haemocompatibility of 2 types of ECC. The Plt count dropped significantly in group B patients: -73% of initial value vs only -27% in group A, (p less than 0.001). In both groups a rise in BTG was shown, but higher in group B, p less than 0.001. At the end of CPB aggregation decreased only slightly in group A after epinephrine and 4-ADP, and decreased hardly in group B with the significant difference between two groups (p less than 0.02 and p less than 0.001, respectively). In group A the mean blood loss was 278 +/- 49 ml/m2 and 483 +/- 67 ml/m2 in group B, p less than 0.001. The mean blood transfusion in group A and B was 198 +/- 82 ml/m2 and 427 +/- 85 ml/m2, respectively (p less than 0.001). We are positive that the elimination of artificial oxygenator from the ECC diminished markedly the decline in Plt count and Plt activation during CPB.</p>","PeriodicalId":75853,"journal":{"name":"Folia haematologica (Leipzig, Germany : 1928)","volume":"117 6","pages":"875-85"},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Haemocompatibility of extracorporeal circulation technique with autooxygenation: influence on platelet function and homologous blood requirement.\",\"authors\":\"J Wojnar, A Bochenek, A M Wnuk-Wojnar, Z Religa, J Hołowiecki\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Forty male patients: group A-autooxygenation and group B-bubble oxygenator used in extracorporeal circulation (ECC) were studied to evaluate the haemocompatibility of 2 types of ECC. The Plt count dropped significantly in group B patients: -73% of initial value vs only -27% in group A, (p less than 0.001). In both groups a rise in BTG was shown, but higher in group B, p less than 0.001. At the end of CPB aggregation decreased only slightly in group A after epinephrine and 4-ADP, and decreased hardly in group B with the significant difference between two groups (p less than 0.02 and p less than 0.001, respectively). In group A the mean blood loss was 278 +/- 49 ml/m2 and 483 +/- 67 ml/m2 in group B, p less than 0.001. The mean blood transfusion in group A and B was 198 +/- 82 ml/m2 and 427 +/- 85 ml/m2, respectively (p less than 0.001). We are positive that the elimination of artificial oxygenator from the ECC diminished markedly the decline in Plt count and Plt activation during CPB.</p>\",\"PeriodicalId\":75853,\"journal\":{\"name\":\"Folia haematologica (Leipzig, Germany : 1928)\",\"volume\":\"117 6\",\"pages\":\"875-85\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Folia haematologica (Leipzig, Germany : 1928)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Folia haematologica (Leipzig, Germany : 1928)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Haemocompatibility of extracorporeal circulation technique with autooxygenation: influence on platelet function and homologous blood requirement.
Forty male patients: group A-autooxygenation and group B-bubble oxygenator used in extracorporeal circulation (ECC) were studied to evaluate the haemocompatibility of 2 types of ECC. The Plt count dropped significantly in group B patients: -73% of initial value vs only -27% in group A, (p less than 0.001). In both groups a rise in BTG was shown, but higher in group B, p less than 0.001. At the end of CPB aggregation decreased only slightly in group A after epinephrine and 4-ADP, and decreased hardly in group B with the significant difference between two groups (p less than 0.02 and p less than 0.001, respectively). In group A the mean blood loss was 278 +/- 49 ml/m2 and 483 +/- 67 ml/m2 in group B, p less than 0.001. The mean blood transfusion in group A and B was 198 +/- 82 ml/m2 and 427 +/- 85 ml/m2, respectively (p less than 0.001). We are positive that the elimination of artificial oxygenator from the ECC diminished markedly the decline in Plt count and Plt activation during CPB.