公共建筑能效指标

Dmitry Stepanov, N. Stepanova, Sergii Onykiienko, Vitaly Martynenko
{"title":"公共建筑能效指标","authors":"Dmitry Stepanov, N. Stepanova, Sergii Onykiienko, Vitaly Martynenko","doi":"10.31649/2311-1429-2023-1-134-139","DOIUrl":null,"url":null,"abstract":"The relevance of paying attention to the energy efficiency of buildings, which will reduce the consumption of fossil fuels and electricity and reduce harmful emissions into the environment, is shown. The energy efficiency indicators of the public building were analyzed, namely the thermal resistance of the enclosing structures, the specific energy demand for heating, cooling and hot water supply, the specific energy consumption of the building for heating and cooling, the specific consumption of primary energy and the specific emissions of greenhouse gases.The effect of increasing the normative thermal resistance of the outer wall of the building on the required thickness of the insulation was evaluated. It is indicated that under the conditions of a large facade glazing ratio and compliance with the regulatory thermal resistance of the fences, the building does not meet the requirements for specific energy consumption for heating, cooling and hot water supply.The influence of the heat source for heating the building on its specific energy consumption, energy efficiency class, specific consumption of primary energy and specific emissions of greenhouse gases was studied. Considered options for using a gas boiler, a condensing gas boiler, electric heaters, a biomass pellet boiler and connection to a centralized heat supply system. The effectiveness of the implementation of reversible heat pump equipment for heating and cooling of buildings is substantiated","PeriodicalId":221366,"journal":{"name":"Modern technology, materials and design in construction","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"INDICATORS OF ENERGY EFFICIENCY OF PUBLIC BUILDING\",\"authors\":\"Dmitry Stepanov, N. Stepanova, Sergii Onykiienko, Vitaly Martynenko\",\"doi\":\"10.31649/2311-1429-2023-1-134-139\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The relevance of paying attention to the energy efficiency of buildings, which will reduce the consumption of fossil fuels and electricity and reduce harmful emissions into the environment, is shown. The energy efficiency indicators of the public building were analyzed, namely the thermal resistance of the enclosing structures, the specific energy demand for heating, cooling and hot water supply, the specific energy consumption of the building for heating and cooling, the specific consumption of primary energy and the specific emissions of greenhouse gases.The effect of increasing the normative thermal resistance of the outer wall of the building on the required thickness of the insulation was evaluated. It is indicated that under the conditions of a large facade glazing ratio and compliance with the regulatory thermal resistance of the fences, the building does not meet the requirements for specific energy consumption for heating, cooling and hot water supply.The influence of the heat source for heating the building on its specific energy consumption, energy efficiency class, specific consumption of primary energy and specific emissions of greenhouse gases was studied. Considered options for using a gas boiler, a condensing gas boiler, electric heaters, a biomass pellet boiler and connection to a centralized heat supply system. The effectiveness of the implementation of reversible heat pump equipment for heating and cooling of buildings is substantiated\",\"PeriodicalId\":221366,\"journal\":{\"name\":\"Modern technology, materials and design in construction\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Modern technology, materials and design in construction\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31649/2311-1429-2023-1-134-139\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Modern technology, materials and design in construction","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31649/2311-1429-2023-1-134-139","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

注意建筑物的能源效率的相关性,这将减少化石燃料和电力的消耗,并减少对环境的有害排放。分析了该公共建筑的能效指标,即围护结构的热阻、采暖、供冷和热水的比能源需求、采暖和供冷的比能源消耗、一次能源消耗和温室气体的比排放。评估了增加建筑外墙的标准热阻对隔热层所需厚度的影响。研究表明,在幕墙玻璃比较大且符合围栏热阻规定的情况下,该建筑不满足采暖、制冷和热水供应的比能耗要求。研究了建筑采暖热源对建筑比能耗、能效等级、一次能源比消耗和温室气体比排放的影响。考虑使用燃气锅炉、冷凝燃气锅炉、电加热器、生物质颗粒锅炉和连接到集中供热系统的选择。采用可逆热泵设备对建筑物进行供暖和制冷的有效性得到了证实
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
INDICATORS OF ENERGY EFFICIENCY OF PUBLIC BUILDING
The relevance of paying attention to the energy efficiency of buildings, which will reduce the consumption of fossil fuels and electricity and reduce harmful emissions into the environment, is shown. The energy efficiency indicators of the public building were analyzed, namely the thermal resistance of the enclosing structures, the specific energy demand for heating, cooling and hot water supply, the specific energy consumption of the building for heating and cooling, the specific consumption of primary energy and the specific emissions of greenhouse gases.The effect of increasing the normative thermal resistance of the outer wall of the building on the required thickness of the insulation was evaluated. It is indicated that under the conditions of a large facade glazing ratio and compliance with the regulatory thermal resistance of the fences, the building does not meet the requirements for specific energy consumption for heating, cooling and hot water supply.The influence of the heat source for heating the building on its specific energy consumption, energy efficiency class, specific consumption of primary energy and specific emissions of greenhouse gases was studied. Considered options for using a gas boiler, a condensing gas boiler, electric heaters, a biomass pellet boiler and connection to a centralized heat supply system. The effectiveness of the implementation of reversible heat pump equipment for heating and cooling of buildings is substantiated
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
THE INFLUENCE OF HEAT-CONDUCTIVE INCLUSIONS ON THE ENERGY EFFICIENCY OF THE EXTERNAL WALLS OF A DWELLING BUILDING WITH A MONOLITHIC FRAME STRUCTURAL CHANGES IN THE ENERGY SUPPLY OF THE HOUSING FUND OF UKRAINE FEATURES OF PLANNING REHABILITATION DEPARTMENTS FOR VETERANS: AN ANALYSIS OF INTERNATIONAL EXPERIENCE INTEGRATION OF ALTERNATIVE ENERGY SOURCES INTO PUBLIC BUILDINGS' HEATING SYSTEMS PRINCIPLES OF APPLICATION OF THE SOIL EINFORCEMENT METHOD WITH HORIZONTAL ELEMENTS IN COMPLEX SOIL CONDITIONS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1