{"title":"正畸近红外光度计及体温计的研制与应用","authors":"G. Brooker, John Sambevski, M. Darendeliler, T. Tang","doi":"10.1109/ICSENST.2017.8304438","DOIUrl":null,"url":null,"abstract":"The paper describes the development, calibration and testing of a custom made photometric-thermometric sensor used to measure the penetration of NIR radiation from an intraoral therapeutic LED source, and the resultant temperature increase in tooth sockets. The difficulty of producing this novel device resides in its small dimensions. However a judicious choice of probes enabled successful development, calibration and in vivo testing. Apart from photometric and thermometric data the heart rate of the patients was also apparent, due to swelling of the capillaries in the gum tissue during systole — the contraction phase — of the cardiac cycle.","PeriodicalId":289209,"journal":{"name":"2017 Eleventh International Conference on Sensing Technology (ICST)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development and application of an orthodontic near infrared photometer and thermometer\",\"authors\":\"G. Brooker, John Sambevski, M. Darendeliler, T. Tang\",\"doi\":\"10.1109/ICSENST.2017.8304438\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper describes the development, calibration and testing of a custom made photometric-thermometric sensor used to measure the penetration of NIR radiation from an intraoral therapeutic LED source, and the resultant temperature increase in tooth sockets. The difficulty of producing this novel device resides in its small dimensions. However a judicious choice of probes enabled successful development, calibration and in vivo testing. Apart from photometric and thermometric data the heart rate of the patients was also apparent, due to swelling of the capillaries in the gum tissue during systole — the contraction phase — of the cardiac cycle.\",\"PeriodicalId\":289209,\"journal\":{\"name\":\"2017 Eleventh International Conference on Sensing Technology (ICST)\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 Eleventh International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2017.8304438\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Eleventh International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2017.8304438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development and application of an orthodontic near infrared photometer and thermometer
The paper describes the development, calibration and testing of a custom made photometric-thermometric sensor used to measure the penetration of NIR radiation from an intraoral therapeutic LED source, and the resultant temperature increase in tooth sockets. The difficulty of producing this novel device resides in its small dimensions. However a judicious choice of probes enabled successful development, calibration and in vivo testing. Apart from photometric and thermometric data the heart rate of the patients was also apparent, due to swelling of the capillaries in the gum tissue during systole — the contraction phase — of the cardiac cycle.