{"title":"建立了环氧树脂在不同环境温度下内放电老化特性的对比分析模型","authors":"R. Schifani","doi":"10.1109/ICSD.1989.69240","DOIUrl":null,"url":null,"abstract":"Different epoxy systems typically used in HV gas-insulated systems were investigated to obtain a more global view of the materials' performance. An accurate scanning microscope analysis was carried out on the aged wall cavity and inside the breakdown channel to obtain information on which to base a model of material performance under high temperature. The time to spontaneous breakdown of samples of identical specimens having a calibrated enclosed void was used as the life criterion. Particular attention was focused on the scatter of the lifetimes. In many cases PD (partial discharge) amplitude distributions were detected during life tests by means of a computerized system, and emphasis was given to their time changes in relation to the testing temperature. This technique made it possible to obtain a more global view of material performance against PD activity for measurements carried out by means of a laboratory test cell. On the basis of the experimental results, a model that provides a deeper insight into resistance to PD, especially when comparative information between different materials is required at temperatures different from the ambient, is proposed.<<ETX>>","PeriodicalId":184126,"journal":{"name":"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"On a model for the comparative analysis of the ageing characteristics of epoxy resins subjected to internal discharges at various environmental temperatures\",\"authors\":\"R. Schifani\",\"doi\":\"10.1109/ICSD.1989.69240\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Different epoxy systems typically used in HV gas-insulated systems were investigated to obtain a more global view of the materials' performance. An accurate scanning microscope analysis was carried out on the aged wall cavity and inside the breakdown channel to obtain information on which to base a model of material performance under high temperature. The time to spontaneous breakdown of samples of identical specimens having a calibrated enclosed void was used as the life criterion. Particular attention was focused on the scatter of the lifetimes. In many cases PD (partial discharge) amplitude distributions were detected during life tests by means of a computerized system, and emphasis was given to their time changes in relation to the testing temperature. This technique made it possible to obtain a more global view of material performance against PD activity for measurements carried out by means of a laboratory test cell. On the basis of the experimental results, a model that provides a deeper insight into resistance to PD, especially when comparative information between different materials is required at temperatures different from the ambient, is proposed.<<ETX>>\",\"PeriodicalId\":184126,\"journal\":{\"name\":\"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSD.1989.69240\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.1989.69240","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

为了更全面地了解材料的性能,研究了高压气体绝缘系统中常用的不同环氧树脂体系。对老化的壁腔和击穿通道内部进行了精确的扫描显微镜分析,以获得材料在高温下性能模型的信息。使用具有校准封闭空隙的相同试样的自发击穿时间作为寿命准则。特别注意的是生命周期的分散。在许多情况下,PD(局部放电)振幅分布是通过计算机系统在寿命测试中检测到的,重点是它们与测试温度相关的时间变化。该技术可以获得更全面的材料性能对PD活性的看法,通过实验室测试单元进行测量。在实验结果的基础上,提出了一个模型,该模型可以更深入地了解PD电阻,特别是当需要在不同环境温度下不同材料之间的比较信息时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On a model for the comparative analysis of the ageing characteristics of epoxy resins subjected to internal discharges at various environmental temperatures
Different epoxy systems typically used in HV gas-insulated systems were investigated to obtain a more global view of the materials' performance. An accurate scanning microscope analysis was carried out on the aged wall cavity and inside the breakdown channel to obtain information on which to base a model of material performance under high temperature. The time to spontaneous breakdown of samples of identical specimens having a calibrated enclosed void was used as the life criterion. Particular attention was focused on the scatter of the lifetimes. In many cases PD (partial discharge) amplitude distributions were detected during life tests by means of a computerized system, and emphasis was given to their time changes in relation to the testing temperature. This technique made it possible to obtain a more global view of material performance against PD activity for measurements carried out by means of a laboratory test cell. On the basis of the experimental results, a model that provides a deeper insight into resistance to PD, especially when comparative information between different materials is required at temperatures different from the ambient, is proposed.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
On the mechanism of partial discharges in gaseous cavities in contact with solid or liquid insulators The initiation and growth of AC tree in polyethylene Effects of the field dependent occupation of electrical-stress-generated traps on the conduction and breakdown of thin SiO/sub 2/ films A model of the electrical breakdown process due to electrical treeing growth Dielectric breakdown and partial discharge in BaTiO/sub 3/ ceramics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1