固态故障限流器发射角控制故障电流分析与控制

J. P. Sharma, Vibhor Chauhan
{"title":"固态故障限流器发射角控制故障电流分析与控制","authors":"J. P. Sharma, Vibhor Chauhan","doi":"10.1109/ICESA.2015.7503405","DOIUrl":null,"url":null,"abstract":"In present scenario of power system, rapid development of power network increase fault current at a level that will affect the system security, stability and reliability. For many existing power system equipments of power system, fault current have exceeded from their withstand capacity. Hence, limiting the fault current to a safe level may reduce failure rate of power system equipment and maintenance cost of the system. This problem is greatly reduced by the use of solid state fault current limiter (SSFCL). The test system is a practical express distribution feeder, Bajaj hospital. In this paper, impacts of firing angle associated with SSFCL control system for symmetrical and unsymmetrical faults are investigated. From results, it is observed that increasing the firing angle leads a reduction in first peak of the fault current.","PeriodicalId":259816,"journal":{"name":"2015 International Conference on Energy Systems and Applications","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Analysis and control of fault current by firing angle control of solid state fault current limiter\",\"authors\":\"J. P. Sharma, Vibhor Chauhan\",\"doi\":\"10.1109/ICESA.2015.7503405\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In present scenario of power system, rapid development of power network increase fault current at a level that will affect the system security, stability and reliability. For many existing power system equipments of power system, fault current have exceeded from their withstand capacity. Hence, limiting the fault current to a safe level may reduce failure rate of power system equipment and maintenance cost of the system. This problem is greatly reduced by the use of solid state fault current limiter (SSFCL). The test system is a practical express distribution feeder, Bajaj hospital. In this paper, impacts of firing angle associated with SSFCL control system for symmetrical and unsymmetrical faults are investigated. From results, it is observed that increasing the firing angle leads a reduction in first peak of the fault current.\",\"PeriodicalId\":259816,\"journal\":{\"name\":\"2015 International Conference on Energy Systems and Applications\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Energy Systems and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICESA.2015.7503405\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Energy Systems and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICESA.2015.7503405","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

在当前的电力系统场景中,随着电网的快速发展,故障电流不断增加,影响系统的安全、稳定和可靠性。电力系统现有的许多电力系统设备,故障电流已超过其承受能力。因此,将故障电流限制在安全范围内,可以降低电力系统设备的故障率,降低系统的维护成本。使用固态故障限流器(SSFCL)大大减少了这个问题。该测试系统是巴贾杰医院一款实用的快递配送馈线。研究了发射角对对称故障和非对称故障控制系统的影响。结果表明,发射角的增大导致故障电流第一峰的减小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis and control of fault current by firing angle control of solid state fault current limiter
In present scenario of power system, rapid development of power network increase fault current at a level that will affect the system security, stability and reliability. For many existing power system equipments of power system, fault current have exceeded from their withstand capacity. Hence, limiting the fault current to a safe level may reduce failure rate of power system equipment and maintenance cost of the system. This problem is greatly reduced by the use of solid state fault current limiter (SSFCL). The test system is a practical express distribution feeder, Bajaj hospital. In this paper, impacts of firing angle associated with SSFCL control system for symmetrical and unsymmetrical faults are investigated. From results, it is observed that increasing the firing angle leads a reduction in first peak of the fault current.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance assessment of steel reheating furnace GREEN SOLUTION (GS): A new initiative for Energy Efficient Computing where Humans and Machines work together Ingenious energy monitoring, control and management of electrical supply Smart parking management system using RFID and OCR MLP-neural network based detection and classification of Power Quality Disturbances
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1