用于测试和校准的有创血压模拟器的研制

Mertcan Özdemir, E. Budak, O. Eroğul
{"title":"用于测试和校准的有创血压模拟器的研制","authors":"Mertcan Özdemir, E. Budak, O. Eroğul","doi":"10.1109/TIPTEKNO50054.2020.9299301","DOIUrl":null,"url":null,"abstract":"Patient monitor modules have various inputs for many vital function measurements. Blood pressure measurement, one of the most important of these measurements, is included in the biomedical engineering field. This study is about the design and implementation of a programmable invasive blood pressure simulator. This device can generate the programmable behavior of the voltage signal corresponding to the blood pressure curve. The user communication interface of the device allows to select the type of signal produced with the LCD and 3 buttons. Broad spectrum of the generated signals corresponding to physiological or pathological blood pressure curves are stored in a programmable memory. The input and output connectors of the device can be directly connected to a patient monitor or IBP Kit to IBP module input. Invasive blood pressure measurement simulation can be used in IBP Kits and monitors developed for training and calibration purposes.","PeriodicalId":426945,"journal":{"name":"2020 Medical Technologies Congress (TIPTEKNO)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of Invasive Blood Pressure Simulator Design for Testing and Calibrating\",\"authors\":\"Mertcan Özdemir, E. Budak, O. Eroğul\",\"doi\":\"10.1109/TIPTEKNO50054.2020.9299301\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Patient monitor modules have various inputs for many vital function measurements. Blood pressure measurement, one of the most important of these measurements, is included in the biomedical engineering field. This study is about the design and implementation of a programmable invasive blood pressure simulator. This device can generate the programmable behavior of the voltage signal corresponding to the blood pressure curve. The user communication interface of the device allows to select the type of signal produced with the LCD and 3 buttons. Broad spectrum of the generated signals corresponding to physiological or pathological blood pressure curves are stored in a programmable memory. The input and output connectors of the device can be directly connected to a patient monitor or IBP Kit to IBP module input. Invasive blood pressure measurement simulation can be used in IBP Kits and monitors developed for training and calibration purposes.\",\"PeriodicalId\":426945,\"journal\":{\"name\":\"2020 Medical Technologies Congress (TIPTEKNO)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 Medical Technologies Congress (TIPTEKNO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TIPTEKNO50054.2020.9299301\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Medical Technologies Congress (TIPTEKNO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIPTEKNO50054.2020.9299301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

病人监护模块有许多重要功能测量的不同输入。血压测量是这些测量中最重要的测量之一,被纳入生物医学工程领域。本研究是关于可编程侵入式血压模拟器的设计与实现。该装置可以生成与血压曲线相对应的可编程行为的电压信号。该设备的用户通信界面允许使用LCD和3个按钮选择产生的信号类型。产生的与生理或病理血压曲线相对应的广谱信号存储在可编程存储器中。设备的输入和输出连接器可直接连接到患者监护仪或IBP Kit到IBP模块输入。侵入性血压测量模拟可用于为培训和校准目的而开发的IBP套件和监视器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of Invasive Blood Pressure Simulator Design for Testing and Calibrating
Patient monitor modules have various inputs for many vital function measurements. Blood pressure measurement, one of the most important of these measurements, is included in the biomedical engineering field. This study is about the design and implementation of a programmable invasive blood pressure simulator. This device can generate the programmable behavior of the voltage signal corresponding to the blood pressure curve. The user communication interface of the device allows to select the type of signal produced with the LCD and 3 buttons. Broad spectrum of the generated signals corresponding to physiological or pathological blood pressure curves are stored in a programmable memory. The input and output connectors of the device can be directly connected to a patient monitor or IBP Kit to IBP module input. Invasive blood pressure measurement simulation can be used in IBP Kits and monitors developed for training and calibration purposes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Multiclass Classification of Brain Cancer with Machine Learning Algorithms Digital Filter Design Based on ARDUINO and Its Applications Use of Velocity Vectors for Cell Classification Under Acoustic Drifting Forces Development of a Full Face Mask during the COVID-19 Epidemic Spread Period TIPTEKNO 2020 Index
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1