基于无源性的三相并网逆变器主动阻尼电流控制稳定性分析

C. Tarasantisuk, N. Phankong
{"title":"基于无源性的三相并网逆变器主动阻尼电流控制稳定性分析","authors":"C. Tarasantisuk, N. Phankong","doi":"10.1109/ECTI-CON58255.2023.10153302","DOIUrl":null,"url":null,"abstract":"With the remarkable growth of renewable energy resources, the grid connected-inverter with current control and stability attracts much attention. Due to the inverter and grid interaction, the stability of the connected inverter is a critical issue. The passivity-based analysis approach, which widely applied to the grid inverter. This paper conducts a comprehensive passivity-based analysis of inverter side current control. Therefore, the paper proposes a passivity-based design method of active damping (AD) in the three-phase grid-connected inverter. The designed Proportional-Resonant (PR) current control system is verified by HIL402 Hardware In the Loop (HIL) environment. The 5 kVA experimental results show the performance and stability of the current control loop.","PeriodicalId":340768,"journal":{"name":"2023 20th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Passivity-Based Stability Analysis for Current Control With Active Damping of Three-phase Grid Connected- Inverter\",\"authors\":\"C. Tarasantisuk, N. Phankong\",\"doi\":\"10.1109/ECTI-CON58255.2023.10153302\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the remarkable growth of renewable energy resources, the grid connected-inverter with current control and stability attracts much attention. Due to the inverter and grid interaction, the stability of the connected inverter is a critical issue. The passivity-based analysis approach, which widely applied to the grid inverter. This paper conducts a comprehensive passivity-based analysis of inverter side current control. Therefore, the paper proposes a passivity-based design method of active damping (AD) in the three-phase grid-connected inverter. The designed Proportional-Resonant (PR) current control system is verified by HIL402 Hardware In the Loop (HIL) environment. The 5 kVA experimental results show the performance and stability of the current control loop.\",\"PeriodicalId\":340768,\"journal\":{\"name\":\"2023 20th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 20th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECTI-CON58255.2023.10153302\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 20th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTI-CON58255.2023.10153302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着可再生能源资源的显著增长,具有电流控制和稳定性的并网逆变器备受关注。由于逆变器与电网的相互作用,逆变器的稳定性是一个关键问题。基于无源性的分析方法,被广泛应用于电网逆变器中。本文对逆变器侧电流控制进行了全面的无源分析。为此,本文提出了一种基于无源性的三相并网逆变器有源阻尼设计方法。所设计的比例谐振(PR)电流控制系统在HIL402硬件在环(HIL)环境中得到验证。5kva的实验结果表明了该电流控制回路的性能和稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Passivity-Based Stability Analysis for Current Control With Active Damping of Three-phase Grid Connected- Inverter
With the remarkable growth of renewable energy resources, the grid connected-inverter with current control and stability attracts much attention. Due to the inverter and grid interaction, the stability of the connected inverter is a critical issue. The passivity-based analysis approach, which widely applied to the grid inverter. This paper conducts a comprehensive passivity-based analysis of inverter side current control. Therefore, the paper proposes a passivity-based design method of active damping (AD) in the three-phase grid-connected inverter. The designed Proportional-Resonant (PR) current control system is verified by HIL402 Hardware In the Loop (HIL) environment. The 5 kVA experimental results show the performance and stability of the current control loop.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Developing and Implementing a Real-Time Mass Health Screening System: MFU.Pass Low-Frequency Wave Propagation in the Cave Developing Steps for Learning Programming through Gamification Hyperbolic Pattern Detection in Ground Penetrating Radar Images Using Faster R-CNN CMA-Based Metasurface-Based Circularly Polarized Patch Antenna for SATCOM Applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1