用于时域漫射光学层析成像的低成本四通道时间相关单光子计数系统的初步结果

J. Bouchard, W. Lemaire, Arnaud Samson, C. Paulin, J. Pratte, Y. B. Lauzière, R. Fontaine
{"title":"用于时域漫射光学层析成像的低成本四通道时间相关单光子计数系统的初步结果","authors":"J. Bouchard, W. Lemaire, Arnaud Samson, C. Paulin, J. Pratte, Y. B. Lauzière, R. Fontaine","doi":"10.1109/MeMeA.2016.7533733","DOIUrl":null,"url":null,"abstract":"Time-domain diffuse optical tomography (TD-DOT) provides information-rich data that have not yet been fully exploited for image reconstruction, notably to increase imaging spatial resolution. Current TD-DOT scanners suffer from a very low sensitivity owing to their small number of detection channels. This leads to excessively long acquisition times for in vivo imaging. To obtain a higher number of detection channels, thus increasing detection density, a low-cost time-correlated single photon counting (TCSPC) system dedicated to TD-DOT imaging was designed and developed, resorting solely to off-the-shelf electronic components to reduce costs, in distinction to custom application-specific integrated circuit (ASIC) solutions. It features 4 input channels with a 13.02 ps bin width and a 18.1 ps FWHM accuracy throughout a measurement dynamic range of 12.5 ns. Each channel includes a leading-edge discriminator, with a programmable threshold, for direct interfacing with off-the-shelf photodetector modules. A software-programmable delay line was added to the channel signal path to compensate for undesired propagation delays. The system also supports a virtually unlimited number of TCSPC channels using a daisy-chain configuration through an onboard Ethernet switch.","PeriodicalId":221120,"journal":{"name":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Preliminary results of a low-cost 4-channel time-correlated single photon counting system for time-domain diffuse optical tomography\",\"authors\":\"J. Bouchard, W. Lemaire, Arnaud Samson, C. Paulin, J. Pratte, Y. B. Lauzière, R. Fontaine\",\"doi\":\"10.1109/MeMeA.2016.7533733\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Time-domain diffuse optical tomography (TD-DOT) provides information-rich data that have not yet been fully exploited for image reconstruction, notably to increase imaging spatial resolution. Current TD-DOT scanners suffer from a very low sensitivity owing to their small number of detection channels. This leads to excessively long acquisition times for in vivo imaging. To obtain a higher number of detection channels, thus increasing detection density, a low-cost time-correlated single photon counting (TCSPC) system dedicated to TD-DOT imaging was designed and developed, resorting solely to off-the-shelf electronic components to reduce costs, in distinction to custom application-specific integrated circuit (ASIC) solutions. It features 4 input channels with a 13.02 ps bin width and a 18.1 ps FWHM accuracy throughout a measurement dynamic range of 12.5 ns. Each channel includes a leading-edge discriminator, with a programmable threshold, for direct interfacing with off-the-shelf photodetector modules. A software-programmable delay line was added to the channel signal path to compensate for undesired propagation delays. The system also supports a virtually unlimited number of TCSPC channels using a daisy-chain configuration through an onboard Ethernet switch.\",\"PeriodicalId\":221120,\"journal\":{\"name\":\"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-08-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA.2016.7533733\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2016.7533733","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

时域漫射光学层析成像(TD-DOT)提供了信息丰富的数据,尚未完全用于图像重建,特别是提高成像空间分辨率。目前的TD-DOT扫描仪由于检测通道数量少,灵敏度很低。这导致体内成像的采集时间过长。为了获得更多的检测通道,从而增加检测密度,设计和开发了一种专门用于TD-DOT成像的低成本时间相关单光子计数(TCSPC)系统,完全依靠现成的电子元件来降低成本,而不是定制的专用集成电路(ASIC)解决方案。它具有4个输入通道,在12.5 ns的测量动态范围内具有13.02 ps的bin宽度和18.1 ps的FWHM精度。每个通道包括一个具有可编程阈值的前沿鉴别器,用于与现成的光电探测器模块直接接口。在信道信号路径中增加了一条软件可编程延迟线,以补偿不希望的传播延迟。该系统还支持几乎无限数量的TCSPC通道,通过板载以太网交换机使用菊花链配置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Preliminary results of a low-cost 4-channel time-correlated single photon counting system for time-domain diffuse optical tomography
Time-domain diffuse optical tomography (TD-DOT) provides information-rich data that have not yet been fully exploited for image reconstruction, notably to increase imaging spatial resolution. Current TD-DOT scanners suffer from a very low sensitivity owing to their small number of detection channels. This leads to excessively long acquisition times for in vivo imaging. To obtain a higher number of detection channels, thus increasing detection density, a low-cost time-correlated single photon counting (TCSPC) system dedicated to TD-DOT imaging was designed and developed, resorting solely to off-the-shelf electronic components to reduce costs, in distinction to custom application-specific integrated circuit (ASIC) solutions. It features 4 input channels with a 13.02 ps bin width and a 18.1 ps FWHM accuracy throughout a measurement dynamic range of 12.5 ns. Each channel includes a leading-edge discriminator, with a programmable threshold, for direct interfacing with off-the-shelf photodetector modules. A software-programmable delay line was added to the channel signal path to compensate for undesired propagation delays. The system also supports a virtually unlimited number of TCSPC channels using a daisy-chain configuration through an onboard Ethernet switch.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Investigation of temperature rise in tissue — Mimicking material induced by a HIFU transducer Influence of fiber Bragg grating length on temperature measurements in laser-irradiated organs Optimal peripheral measurement point for the assessment of preterm patients in intensive care units Classification of cognitive and resting states of the brain using EEG features Scoring systems in dermatology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1