{"title":"现代开关电源负载的谐波消除","authors":"A. Collin, C. Cresswell, S. Djokic","doi":"10.1109/ICHQP.2010.5625422","DOIUrl":null,"url":null,"abstract":"Switch-mode power supplies (SMPS) are one of the most common category of loads, typically found in large numbers in modern power supply systems. These devices usually draw non-linear current and are, therefore, significant sources of harmonics. Although it is well known that the presence of harmonics will result in negative effects (e.g. higher thermal stresses and overloading, or increased neutral conductor currents), the assessment of the actual harmonic levels is not a simple task.","PeriodicalId":180078,"journal":{"name":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":"{\"title\":\"Harmonic cancellation of modern switch-mode power supply load\",\"authors\":\"A. Collin, C. Cresswell, S. Djokic\",\"doi\":\"10.1109/ICHQP.2010.5625422\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Switch-mode power supplies (SMPS) are one of the most common category of loads, typically found in large numbers in modern power supply systems. These devices usually draw non-linear current and are, therefore, significant sources of harmonics. Although it is well known that the presence of harmonics will result in negative effects (e.g. higher thermal stresses and overloading, or increased neutral conductor currents), the assessment of the actual harmonic levels is not a simple task.\",\"PeriodicalId\":180078,\"journal\":{\"name\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"26\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2010.5625422\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2010.5625422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Harmonic cancellation of modern switch-mode power supply load
Switch-mode power supplies (SMPS) are one of the most common category of loads, typically found in large numbers in modern power supply systems. These devices usually draw non-linear current and are, therefore, significant sources of harmonics. Although it is well known that the presence of harmonics will result in negative effects (e.g. higher thermal stresses and overloading, or increased neutral conductor currents), the assessment of the actual harmonic levels is not a simple task.