基于高压断路器症状、失效类型和报废标准的性能评价

T. Suwanasri, C. Suwanasri, Sakda Nobnorp, S. Wattanawongpitak
{"title":"基于高压断路器症状、失效类型和报废标准的性能评价","authors":"T. Suwanasri, C. Suwanasri, Sakda Nobnorp, S. Wattanawongpitak","doi":"10.1109/ECTICON.2013.6559528","DOIUrl":null,"url":null,"abstract":"The requirement to renovate the deteriorated and aging electrical asset is now playing a significant role on the quality of electrical supply. Thus this paper presents the performance evaluation of 115 kV circuit breaker in power substation. The degraded high voltage circuit breakers should be assessed and clearly identified as supported reasons for planning the renovation task of electrical asset. This performance assessment based on symptom, failed-type and obsolescence criteria are used to clearly identify the visible deterioration. The proposed method was implemented with sixteen circuit breakers in two high voltage substations in Thai electrical utility as examples for illustrating the application of the method. The results show that performances of high voltage circuit breakers are in three stages for healthy, moderate, and risk performance. In the risk stage, the circuit breaker should be intensively cared. The proposed method can be further adapted to other high voltage equipment in power substation.","PeriodicalId":273802,"journal":{"name":"2013 10th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology","volume":"05 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Performance evaluation based on symptom, failed-type and obsolescence criteria of high voltage circuit breaker\",\"authors\":\"T. Suwanasri, C. Suwanasri, Sakda Nobnorp, S. Wattanawongpitak\",\"doi\":\"10.1109/ECTICON.2013.6559528\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The requirement to renovate the deteriorated and aging electrical asset is now playing a significant role on the quality of electrical supply. Thus this paper presents the performance evaluation of 115 kV circuit breaker in power substation. The degraded high voltage circuit breakers should be assessed and clearly identified as supported reasons for planning the renovation task of electrical asset. This performance assessment based on symptom, failed-type and obsolescence criteria are used to clearly identify the visible deterioration. The proposed method was implemented with sixteen circuit breakers in two high voltage substations in Thai electrical utility as examples for illustrating the application of the method. The results show that performances of high voltage circuit breakers are in three stages for healthy, moderate, and risk performance. In the risk stage, the circuit breaker should be intensively cared. The proposed method can be further adapted to other high voltage equipment in power substation.\",\"PeriodicalId\":273802,\"journal\":{\"name\":\"2013 10th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology\",\"volume\":\"05 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 10th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECTICON.2013.6559528\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 10th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTICON.2013.6559528","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

对劣化、老化的电力资产进行改造的要求,对电力供应质量产生了重大影响。为此,本文对变电站115 kV断路器的性能进行了评价。对降级的高压断路器进行评估,明确认定为电气资产改造任务规划的支撑理由。这种基于症状、失效类型和过时标准的性能评估用于清楚地识别可见的劣化。以泰国电力公司两个高压变电站的16个断路器为例,说明了该方法的应用。结果表明,高压断路器的性能分为健康性能、中等性能和风险性能三个阶段。在危险阶段,应对断路器进行集中护理。该方法可进一步适用于变电所其他高压设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance evaluation based on symptom, failed-type and obsolescence criteria of high voltage circuit breaker
The requirement to renovate the deteriorated and aging electrical asset is now playing a significant role on the quality of electrical supply. Thus this paper presents the performance evaluation of 115 kV circuit breaker in power substation. The degraded high voltage circuit breakers should be assessed and clearly identified as supported reasons for planning the renovation task of electrical asset. This performance assessment based on symptom, failed-type and obsolescence criteria are used to clearly identify the visible deterioration. The proposed method was implemented with sixteen circuit breakers in two high voltage substations in Thai electrical utility as examples for illustrating the application of the method. The results show that performances of high voltage circuit breakers are in three stages for healthy, moderate, and risk performance. In the risk stage, the circuit breaker should be intensively cared. The proposed method can be further adapted to other high voltage equipment in power substation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
CPW-fed dual wideband using stub split-ring rectangular slot antenna A comparative study on different techniques for Thai part-of-speech tagging Bismuth doped ZnO films as anti-reflection coatings for solar cells Multi-channel Collection Tree Protocol for Wireless Sensor Networks Multi-robot coordination using switching of methods for deriving equilibrium in game theory
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1