{"title":"外压作用下腐蚀环球壳的屈曲","authors":"J. Błachut","doi":"10.1115/PVP2018-84309","DOIUrl":null,"url":null,"abstract":"The current paper examines the effects of corrosion induced wall thinning on buckling of domed closures onto cylindrical vessels. It is assumed that corrosion is axisymmetric and that the wall is corroded on inside, only. The ratio of corroded wall thickness, tc, to the non-corroded thickness, t, is varied between 0.10 ≤ tc/t ≤ 1.0. Both depth of corrosion and its meridional extend are varied during numerical calculations. Three modelling scenarios for placement of corrosion are considered: (i) corrosion confined to the knuckle, (ii) corrosion spanning evenly the knuckle and spherical parts, and (iii) patchtype area positioned at the apex. Numerical results indicate that the following factors influence buckling performance of the dome: (i) meridional position of corroded area, (ii) depth of corrosion itself, and (iii) meridional span of corroded wall. For example, wall thinning of 10 % over 10 % of meridional length causes almost 20 % drop in buckling strength. The largest drop of load carrying capacity is found when the corroded wall is at the knuckle/crown junction. Here it is shown that assessment of strength based on the collapse mechanism is not only wrong but dangerous. For the case of the corroded dome, the collapse pressure overestimates the load carrying capacity associated with asymmetric bifurcation buckling by 40 %.","PeriodicalId":384066,"journal":{"name":"Volume 3B: Design and Analysis","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Buckling of Corroded Torispherical Shells Under External Pressure\",\"authors\":\"J. Błachut\",\"doi\":\"10.1115/PVP2018-84309\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The current paper examines the effects of corrosion induced wall thinning on buckling of domed closures onto cylindrical vessels. It is assumed that corrosion is axisymmetric and that the wall is corroded on inside, only. The ratio of corroded wall thickness, tc, to the non-corroded thickness, t, is varied between 0.10 ≤ tc/t ≤ 1.0. Both depth of corrosion and its meridional extend are varied during numerical calculations. Three modelling scenarios for placement of corrosion are considered: (i) corrosion confined to the knuckle, (ii) corrosion spanning evenly the knuckle and spherical parts, and (iii) patchtype area positioned at the apex. Numerical results indicate that the following factors influence buckling performance of the dome: (i) meridional position of corroded area, (ii) depth of corrosion itself, and (iii) meridional span of corroded wall. For example, wall thinning of 10 % over 10 % of meridional length causes almost 20 % drop in buckling strength. The largest drop of load carrying capacity is found when the corroded wall is at the knuckle/crown junction. Here it is shown that assessment of strength based on the collapse mechanism is not only wrong but dangerous. For the case of the corroded dome, the collapse pressure overestimates the load carrying capacity associated with asymmetric bifurcation buckling by 40 %.\",\"PeriodicalId\":384066,\"journal\":{\"name\":\"Volume 3B: Design and Analysis\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 3B: Design and Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/PVP2018-84309\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3B: Design and Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/PVP2018-84309","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文研究了腐蚀引起的壁变薄对圆柱形容器的圆顶闭包屈曲的影响。假定腐蚀是轴对称的,并且仅在内壁腐蚀。腐蚀壁厚tc与未腐蚀壁厚t之比在0.10≤tc/t≤1.0之间变化。在数值计算中,腐蚀深度和经向延伸都是不同的。考虑了腐蚀位置的三种建模情景:(i)腐蚀局限于关节,(ii)腐蚀均匀地跨越关节和球形部分,以及(iii)位于顶部的斑块型区域。数值计算结果表明,影响穹顶屈曲性能的因素有:(1)腐蚀区域的子午位置,(2)腐蚀本身的深度,以及(3)腐蚀壁的子午跨度。例如,在子午长度的10%以上,壁厚减薄10%会导致屈曲强度下降近20%。腐蚀壁的承载能力下降幅度最大的是指节/冠交界处。这表明,基于破坏机制的强度评估不仅是错误的,而且是危险的。对于腐蚀的穹顶,破坏压力高估了不对称分岔屈曲的承载能力40%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Buckling of Corroded Torispherical Shells Under External Pressure
The current paper examines the effects of corrosion induced wall thinning on buckling of domed closures onto cylindrical vessels. It is assumed that corrosion is axisymmetric and that the wall is corroded on inside, only. The ratio of corroded wall thickness, tc, to the non-corroded thickness, t, is varied between 0.10 ≤ tc/t ≤ 1.0. Both depth of corrosion and its meridional extend are varied during numerical calculations. Three modelling scenarios for placement of corrosion are considered: (i) corrosion confined to the knuckle, (ii) corrosion spanning evenly the knuckle and spherical parts, and (iii) patchtype area positioned at the apex. Numerical results indicate that the following factors influence buckling performance of the dome: (i) meridional position of corroded area, (ii) depth of corrosion itself, and (iii) meridional span of corroded wall. For example, wall thinning of 10 % over 10 % of meridional length causes almost 20 % drop in buckling strength. The largest drop of load carrying capacity is found when the corroded wall is at the knuckle/crown junction. Here it is shown that assessment of strength based on the collapse mechanism is not only wrong but dangerous. For the case of the corroded dome, the collapse pressure overestimates the load carrying capacity associated with asymmetric bifurcation buckling by 40 %.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Comparative Evaluation of Finite Element Modeling of Creep Deformation of Fuel Channels in CANDU® Nuclear Reactors Fitness for Service Assessment and Repair of the Liner of a High Pressure Heat Exchanger An Iterative Method for Solving Static Piping Analysis Including Friction Between Pipes and Support Development of New Design Fatigue Curves in Japan: Discussion of Best-Fit Curves Based on Large-Scale Fatigue Tests of Carbon and Low-Alloy Steel Plates Assembly of Bolted Flanged and Support Joints for Use in Elevated Temperature Exhaust Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1