低电流强度颅电刺激样机的符合性评价及智能手机应用

I. Gunawan, Gita Rindang Lestari, R. N. Hidayati, E. Supriyanto, Vita Nurdinawati
{"title":"低电流强度颅电刺激样机的符合性评价及智能手机应用","authors":"I. Gunawan, Gita Rindang Lestari, R. N. Hidayati, E. Supriyanto, Vita Nurdinawati","doi":"10.1109/ICHE55634.2022.10179889","DOIUrl":null,"url":null,"abstract":"We designed cranial electro stimulation with a low current intensity, which is applied to the head indirectly using direct current intensity. Unidirectional transcranial stimulation is a non-invasive brain stimulation method that has been shown to be effective in modulating cortical excitability and guiding human perception and behavior. The purpose of this research is to design a low-current-intensity cranial electro-stimulation therapy device that is affordable, dependable, and feasible. The CES has a frequency range of 10, 13, and 15 Hz and treatment times of 15, 30, and 45 minutes. The CES generates a current intensity of 0.25, 0.5, 0.75, and 1 mA. The design of CES prototypes was tested at Balai Pengamanan Fasilitas Kesehatan (BPFK) Jakarta, Indonesia, which includes electrical safety measurement, performance testing, and battery reliability. The BPFK Jakarta declares that the test meets the requirements of the testing method and that the tool has passed the test. In addition, the tool has been issued a certificate with no YK.01.03/XLVII.2/PK/2022.","PeriodicalId":289905,"journal":{"name":"2022 International Conference on Healthcare Engineering (ICHE)","volume":"63 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Conformity Evaluation of Cranial Electro-stimulation Prototype with Low Current Intensity and Smartphone Application\",\"authors\":\"I. Gunawan, Gita Rindang Lestari, R. N. Hidayati, E. Supriyanto, Vita Nurdinawati\",\"doi\":\"10.1109/ICHE55634.2022.10179889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We designed cranial electro stimulation with a low current intensity, which is applied to the head indirectly using direct current intensity. Unidirectional transcranial stimulation is a non-invasive brain stimulation method that has been shown to be effective in modulating cortical excitability and guiding human perception and behavior. The purpose of this research is to design a low-current-intensity cranial electro-stimulation therapy device that is affordable, dependable, and feasible. The CES has a frequency range of 10, 13, and 15 Hz and treatment times of 15, 30, and 45 minutes. The CES generates a current intensity of 0.25, 0.5, 0.75, and 1 mA. The design of CES prototypes was tested at Balai Pengamanan Fasilitas Kesehatan (BPFK) Jakarta, Indonesia, which includes electrical safety measurement, performance testing, and battery reliability. The BPFK Jakarta declares that the test meets the requirements of the testing method and that the tool has passed the test. In addition, the tool has been issued a certificate with no YK.01.03/XLVII.2/PK/2022.\",\"PeriodicalId\":289905,\"journal\":{\"name\":\"2022 International Conference on Healthcare Engineering (ICHE)\",\"volume\":\"63 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Healthcare Engineering (ICHE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHE55634.2022.10179889\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Healthcare Engineering (ICHE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHE55634.2022.10179889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们设计了一种低电流强度的颅电刺激,它通过直流电强度间接作用于头部。单向经颅刺激是一种非侵入性的脑刺激方法,已被证明在调节皮质兴奋性和指导人类感知和行为方面是有效的。本研究的目的是设计一种经济、可靠、可行的低电流强度颅电刺激治疗装置。CES的频率范围为10、13和15 Hz,治疗时间为15、30和45分钟。可产生0.25、0.5、0.75和1ma的电流强度。CES原型机的设计在印度尼西亚雅加达的Balai Pengamanan Fasilitas Kesehatan (BPFK)进行了测试,包括电气安全测量、性能测试和电池可靠性。BPFK Jakarta声明该测试符合测试方法的要求,并且该工具已通过测试。此外,该工具已获得不含YK.01.03/XLVII.2/PK/2022的证书。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Conformity Evaluation of Cranial Electro-stimulation Prototype with Low Current Intensity and Smartphone Application
We designed cranial electro stimulation with a low current intensity, which is applied to the head indirectly using direct current intensity. Unidirectional transcranial stimulation is a non-invasive brain stimulation method that has been shown to be effective in modulating cortical excitability and guiding human perception and behavior. The purpose of this research is to design a low-current-intensity cranial electro-stimulation therapy device that is affordable, dependable, and feasible. The CES has a frequency range of 10, 13, and 15 Hz and treatment times of 15, 30, and 45 minutes. The CES generates a current intensity of 0.25, 0.5, 0.75, and 1 mA. The design of CES prototypes was tested at Balai Pengamanan Fasilitas Kesehatan (BPFK) Jakarta, Indonesia, which includes electrical safety measurement, performance testing, and battery reliability. The BPFK Jakarta declares that the test meets the requirements of the testing method and that the tool has passed the test. In addition, the tool has been issued a certificate with no YK.01.03/XLVII.2/PK/2022.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fertility Assessment Model For Embryo Grading Using Convolutional Neural Network (CNN) Beneficial Effect of Amniotic Membrane Stem Cell and Vitamin C after Fractional Carbon-Dioxide Laser for Photoaging Treatment in Asian Skin A Review on Human Stress Detection using Biosignal Based on Image Processing Technique Analytics of the COVID-19 Death According to the Vaccine Dose: Malaysia Case Study Depression Risk Model Among Malaysians
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1