紧凑型脉冲“冷阴极”-闪光x射线管电源装置与固态开开关

A. Dunaevsky, K. Golubinsky, A. Lomako, O. Morgun
{"title":"紧凑型脉冲“冷阴极”-闪光x射线管电源装置与固态开开关","authors":"A. Dunaevsky, K. Golubinsky, A. Lomako, O. Morgun","doi":"10.1109/BEAMS.1998.822440","DOIUrl":null,"url":null,"abstract":"From early 70s X-ray compact pulse X-ray generators with cold cathode X-ray tubes could be found in various industry and science applications. High voltage pulse in our generator is produced by semiconductor opening switch implementation in inductive energy storage circuit. Idea of current flow breaking is widely used in high-power technique, where plasma opening switches opened a new page in power transitions. A lot of investigations carried out in the field of pulsed power solid-state opening switches both specially controlled and based on commercial high-voltage diodes. To investigate the behaviors of commercially available high-voltage diodes when implemented as solid-state opening switches we studied a number of high-voltage diodes with breakdown voltage more than 5 kV.","PeriodicalId":410823,"journal":{"name":"12th International Conference on High-Power Particle Beams. BEAMS'98. Proceedings (Cat. No.98EX103)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Compact pulse \\\"cold cathode\\\"-flash X-ray tube power supply unit with solid-state opening switch\",\"authors\":\"A. Dunaevsky, K. Golubinsky, A. Lomako, O. Morgun\",\"doi\":\"10.1109/BEAMS.1998.822440\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"From early 70s X-ray compact pulse X-ray generators with cold cathode X-ray tubes could be found in various industry and science applications. High voltage pulse in our generator is produced by semiconductor opening switch implementation in inductive energy storage circuit. Idea of current flow breaking is widely used in high-power technique, where plasma opening switches opened a new page in power transitions. A lot of investigations carried out in the field of pulsed power solid-state opening switches both specially controlled and based on commercial high-voltage diodes. To investigate the behaviors of commercially available high-voltage diodes when implemented as solid-state opening switches we studied a number of high-voltage diodes with breakdown voltage more than 5 kV.\",\"PeriodicalId\":410823,\"journal\":{\"name\":\"12th International Conference on High-Power Particle Beams. BEAMS'98. Proceedings (Cat. No.98EX103)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"12th International Conference on High-Power Particle Beams. BEAMS'98. Proceedings (Cat. No.98EX103)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BEAMS.1998.822440\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"12th International Conference on High-Power Particle Beams. BEAMS'98. Proceedings (Cat. No.98EX103)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BEAMS.1998.822440","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

从70年代初开始,冷阴极x射线管的x射线紧凑型脉冲x射线发生器可以在各种工业和科学应用中找到。本发电机的高压脉冲是通过电感储能电路中的半导体开断开关实现的。电流断流思想在大功率技术中得到了广泛的应用,等离子体开断开关在大功率技术中开辟了新的一页。在脉冲功率固态开路开关领域进行了大量的研究,包括特殊控制的和基于商用高压二极管的。为了研究商用高压二极管作为固态开路开关时的行为,我们研究了一些击穿电压超过5 kV的高压二极管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Compact pulse "cold cathode"-flash X-ray tube power supply unit with solid-state opening switch
From early 70s X-ray compact pulse X-ray generators with cold cathode X-ray tubes could be found in various industry and science applications. High voltage pulse in our generator is produced by semiconductor opening switch implementation in inductive energy storage circuit. Idea of current flow breaking is widely used in high-power technique, where plasma opening switches opened a new page in power transitions. A lot of investigations carried out in the field of pulsed power solid-state opening switches both specially controlled and based on commercial high-voltage diodes. To investigate the behaviors of commercially available high-voltage diodes when implemented as solid-state opening switches we studied a number of high-voltage diodes with breakdown voltage more than 5 kV.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Applications of dielectric barrier discharges The prospect for fusion energy with light ions A study of parameters useful for describing plasma-opening switches Wire array Z-pinch insights for high X-ray power generation Applications of intense pulsed light ion beams to materials science
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1