一种无辐射导尿管导航自动配准方法

Caspar Gruijthuijsen, Benoît Rosa, P. T. Tran, J. Sloten, E. V. Poorten, D. Reynaerts
{"title":"一种无辐射导尿管导航自动配准方法","authors":"Caspar Gruijthuijsen, Benoît Rosa, P. T. Tran, J. Sloten, E. V. Poorten, D. Reynaerts","doi":"10.1142/S2424905X16400092","DOIUrl":null,"url":null,"abstract":"Catheter navigation is typically based on fluoroscopy. This implies exposure to harmful radiation, lack of depth perception and limited soft-tissue contrast. Catheter navigation would benefit from guidance that makes better use of detailed pre-operatively acquired MR/CT images, while reducing radiation exposure and improving spatial awareness of the catheter pose and shape. A prerequisite for such guidance is an accurate registration between the catheter tracking system and the MR/CT scans. Existing registration methods are lengthy and cumbersome as they require a lot of user interaction. This forms a major obstacle for their adoption into clinical practice. This paper proposes a radiation-free registration method that minimizes the impact on the surgical workflow and avoids most user interaction. The method relies on catheters with embedded sensors that provide intra-operative data that can either belong to the vessel wall or to the lumen of the vessel. Based on the acquired surface and lumen points an accurate registration is computed automatically, with minimal user interaction. Validation of the proposed method is performed on a synthetic yet realistic aorta phantom. Input from electromagnetic tracking, force sensing, and intra-vascular ultrasound are used as intra-operative sensory data.","PeriodicalId":447761,"journal":{"name":"J. Medical Robotics Res.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"An Automatic Registration Method for Radiation-Free Catheter Navigation Guidance\",\"authors\":\"Caspar Gruijthuijsen, Benoît Rosa, P. T. Tran, J. Sloten, E. V. Poorten, D. Reynaerts\",\"doi\":\"10.1142/S2424905X16400092\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Catheter navigation is typically based on fluoroscopy. This implies exposure to harmful radiation, lack of depth perception and limited soft-tissue contrast. Catheter navigation would benefit from guidance that makes better use of detailed pre-operatively acquired MR/CT images, while reducing radiation exposure and improving spatial awareness of the catheter pose and shape. A prerequisite for such guidance is an accurate registration between the catheter tracking system and the MR/CT scans. Existing registration methods are lengthy and cumbersome as they require a lot of user interaction. This forms a major obstacle for their adoption into clinical practice. This paper proposes a radiation-free registration method that minimizes the impact on the surgical workflow and avoids most user interaction. The method relies on catheters with embedded sensors that provide intra-operative data that can either belong to the vessel wall or to the lumen of the vessel. Based on the acquired surface and lumen points an accurate registration is computed automatically, with minimal user interaction. Validation of the proposed method is performed on a synthetic yet realistic aorta phantom. Input from electromagnetic tracking, force sensing, and intra-vascular ultrasound are used as intra-operative sensory data.\",\"PeriodicalId\":447761,\"journal\":{\"name\":\"J. Medical Robotics Res.\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"J. Medical Robotics Res.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1142/S2424905X16400092\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"J. Medical Robotics Res.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S2424905X16400092","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

导尿管导航通常基于透视。这意味着暴露于有害辐射,缺乏深度感知和有限的软组织对比。导尿管导航将受益于更好地利用术前获得的详细MR/CT图像的指导,同时减少辐射暴露,提高导管姿势和形状的空间意识。这种引导的先决条件是导管跟踪系统和MR/CT扫描之间的准确注册。现有的注册方法冗长而繁琐,因为它们需要大量的用户交互。这构成了将其应用于临床实践的主要障碍。本文提出了一种无辐射的配准方法,将对手术工作流程的影响降到最低,并避免了大多数用户交互。该方法依赖于带有嵌入式传感器的导管,这些传感器可以提供属于血管壁或血管管腔的术中数据。根据获得的表面和流明点,自动计算准确的配准,用户交互最小。所提出的方法的验证是在一个合成的但现实的主动脉幻影上进行的。来自电磁跟踪、力传感和血管内超声的输入被用作术中感觉数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An Automatic Registration Method for Radiation-Free Catheter Navigation Guidance
Catheter navigation is typically based on fluoroscopy. This implies exposure to harmful radiation, lack of depth perception and limited soft-tissue contrast. Catheter navigation would benefit from guidance that makes better use of detailed pre-operatively acquired MR/CT images, while reducing radiation exposure and improving spatial awareness of the catheter pose and shape. A prerequisite for such guidance is an accurate registration between the catheter tracking system and the MR/CT scans. Existing registration methods are lengthy and cumbersome as they require a lot of user interaction. This forms a major obstacle for their adoption into clinical practice. This paper proposes a radiation-free registration method that minimizes the impact on the surgical workflow and avoids most user interaction. The method relies on catheters with embedded sensors that provide intra-operative data that can either belong to the vessel wall or to the lumen of the vessel. Based on the acquired surface and lumen points an accurate registration is computed automatically, with minimal user interaction. Validation of the proposed method is performed on a synthetic yet realistic aorta phantom. Input from electromagnetic tracking, force sensing, and intra-vascular ultrasound are used as intra-operative sensory data.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Calibration and Evaluation of a Motion Measurement System for PET Imaging Studies Automatic Detection of Out-of-body Frames in Surgical Videos for Privacy Protection Using Self-supervised Learning and Minimal Labels A Novel Mechanical Design of a Wearable Fingertip Haptic Device for Remote Meniscus Palpation A Surgical Robotic Framework for Safe and Autonomous Data-Driven Learning and Manipulation of an Unknown Deformable Tissue with an Integrated Critical Space Development and Testing of a Durable and Novel Breast Phantom for Robotic Autonomous Ultrasound Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1