{"title":"过电压保护元件建模的时频结合表征方法","authors":"Stanislav Scheier, Dominik Deelmann, S. Frei, C. Widemann, W. Mathis","doi":"10.1109/ISEMC.2015.7256368","DOIUrl":null,"url":null,"abstract":"Nonlinear voltage sensitive protection elements, e.g. Multi-Layer Varistor (MLV) or Transient Voltage Suppressor (TVS) are useful to protect IC pins from ESD on System Level. Such elements might exhibit a significant voltage overshoot for fast transients. This work describes a combined time and frequency domain characterization method and its application to an MLV. Impedance measurements with VNA at different DC-bias points are used for model identification and parameterization. The static nonlinear IV-behavior of nonlinear model part at higher voltages and currents is extrapolated with a TLP IV-curve. The model is successfully validated with ESD pulses in time domain. The transient behavior including the occurring voltage overshoot can be reproduced with high accuracy.","PeriodicalId":412708,"journal":{"name":"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)","volume":"304 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A combined time and frequency domain characterization method for modeling of overvoltage protection elements\",\"authors\":\"Stanislav Scheier, Dominik Deelmann, S. Frei, C. Widemann, W. Mathis\",\"doi\":\"10.1109/ISEMC.2015.7256368\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nonlinear voltage sensitive protection elements, e.g. Multi-Layer Varistor (MLV) or Transient Voltage Suppressor (TVS) are useful to protect IC pins from ESD on System Level. Such elements might exhibit a significant voltage overshoot for fast transients. This work describes a combined time and frequency domain characterization method and its application to an MLV. Impedance measurements with VNA at different DC-bias points are used for model identification and parameterization. The static nonlinear IV-behavior of nonlinear model part at higher voltages and currents is extrapolated with a TLP IV-curve. The model is successfully validated with ESD pulses in time domain. The transient behavior including the occurring voltage overshoot can be reproduced with high accuracy.\",\"PeriodicalId\":412708,\"journal\":{\"name\":\"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)\",\"volume\":\"304 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2015.7256368\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2015.7256368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

非线性电压敏感保护元件,例如多层压敏电阻(MLV)或瞬态电压抑制器(TVS)可用于保护IC引脚免受系统级ESD的影响。这类元件在快速瞬变时可能表现出明显的电压超调。本文介绍了一种时域和频域相结合的表征方法及其在MLV中的应用。利用VNA在不同直流偏置点上的阻抗测量用于模型识别和参数化。用TLP iv曲线外推了非线性模型部件在高电压和高电流下的静态非线性iv行为。该模型在时域上成功地用ESD脉冲进行了验证。可以高精度地再现瞬态行为,包括发生的电压超调。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A combined time and frequency domain characterization method for modeling of overvoltage protection elements
Nonlinear voltage sensitive protection elements, e.g. Multi-Layer Varistor (MLV) or Transient Voltage Suppressor (TVS) are useful to protect IC pins from ESD on System Level. Such elements might exhibit a significant voltage overshoot for fast transients. This work describes a combined time and frequency domain characterization method and its application to an MLV. Impedance measurements with VNA at different DC-bias points are used for model identification and parameterization. The static nonlinear IV-behavior of nonlinear model part at higher voltages and currents is extrapolated with a TLP IV-curve. The model is successfully validated with ESD pulses in time domain. The transient behavior including the occurring voltage overshoot can be reproduced with high accuracy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
AutoCAD application for LPS, grounding and EMC problems Finite element simulation of the frequency-dependent polarization of biological cells On the need of certification in computational electromagnetics based engineering services MRI image distortion due to magnetic materials in medical implants DWT analysis of high order harmonics influence over distorted regimes with fast variable loads
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1