G Mucignat, G L Tarabini-Castellani, L Pascoli, W De Cal, G Bruschetta, P De Paoli, G Santini
{"title":"革兰氏阴性杆菌敏感系统的初步评价。","authors":"G Mucignat, G L Tarabini-Castellani, L Pascoli, W De Cal, G Bruschetta, P De Paoli, G Santini","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The automated microdilution Sensititre System (Sensititre, LtD.) was evaluated for the identification of 120 clinically isolated fermenter and non-fermenter Gram negative bacilli and of 12 ATCC reference strains (American Type Culture Collection). Daily and overnight (5 and 18 hours) identifications were performed according to the manufacturer. In both cases, the results were compared with those obtained with the overnight API 20E (API System, La Balme les Grottes, Montalieu Vercieu) used as reference method. Concordance between the results obtained after 5 hrs of incubation and those obtained with API 20E was found in 65% of cases (acceptable identification criteria with probability over 80%). When results were determined after 18 hrs of incubation (identification criteria with probably over 80%) concordance was found in 82.5%. Reproducibility obtained by repeated (10 times) identification with four different strains was 100% both at 5 hrs and 18 hrs. Identification accuracy of the 12 ATCC strains was 8/12 (66.6%) after 5 hrs and 12/12 (100%) after 18 hrs.</p>","PeriodicalId":77264,"journal":{"name":"Microbiologica","volume":"14 3","pages":"261-5"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preliminary evaluation of sensititre system for identifying gram-negative bacilli.\",\"authors\":\"G Mucignat, G L Tarabini-Castellani, L Pascoli, W De Cal, G Bruschetta, P De Paoli, G Santini\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The automated microdilution Sensititre System (Sensititre, LtD.) was evaluated for the identification of 120 clinically isolated fermenter and non-fermenter Gram negative bacilli and of 12 ATCC reference strains (American Type Culture Collection). Daily and overnight (5 and 18 hours) identifications were performed according to the manufacturer. In both cases, the results were compared with those obtained with the overnight API 20E (API System, La Balme les Grottes, Montalieu Vercieu) used as reference method. Concordance between the results obtained after 5 hrs of incubation and those obtained with API 20E was found in 65% of cases (acceptable identification criteria with probability over 80%). When results were determined after 18 hrs of incubation (identification criteria with probably over 80%) concordance was found in 82.5%. Reproducibility obtained by repeated (10 times) identification with four different strains was 100% both at 5 hrs and 18 hrs. Identification accuracy of the 12 ATCC strains was 8/12 (66.6%) after 5 hrs and 12/12 (100%) after 18 hrs.</p>\",\"PeriodicalId\":77264,\"journal\":{\"name\":\"Microbiologica\",\"volume\":\"14 3\",\"pages\":\"261-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microbiologica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microbiologica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
采用自动微稀释敏敏系统(Sensititre, LtD.)鉴定120株临床分离的发酵和非发酵革兰氏阴性杆菌和12株ATCC参考菌株(American Type Culture Collection)。根据制造商进行每日和夜间(5和18小时)鉴定。在这两种情况下,将结果与隔夜API 20E (API System, La Balme les Grottes, Montalieu Vercieu)作为参考方法获得的结果进行比较。65%的病例在孵育5小时后获得的结果与API 20E获得的结果一致(可接受的识别标准,概率超过80%)。孵育18小时后确定结果(鉴定标准可能超过80%),82.5%的人发现一致性。4种不同菌株在5 h和18 h的重复性均为100%。5 h后对12株ATCC的鉴定准确率为8/12 (66.6%),18 h后为12/12(100%)。
Preliminary evaluation of sensititre system for identifying gram-negative bacilli.
The automated microdilution Sensititre System (Sensititre, LtD.) was evaluated for the identification of 120 clinically isolated fermenter and non-fermenter Gram negative bacilli and of 12 ATCC reference strains (American Type Culture Collection). Daily and overnight (5 and 18 hours) identifications were performed according to the manufacturer. In both cases, the results were compared with those obtained with the overnight API 20E (API System, La Balme les Grottes, Montalieu Vercieu) used as reference method. Concordance between the results obtained after 5 hrs of incubation and those obtained with API 20E was found in 65% of cases (acceptable identification criteria with probability over 80%). When results were determined after 18 hrs of incubation (identification criteria with probably over 80%) concordance was found in 82.5%. Reproducibility obtained by repeated (10 times) identification with four different strains was 100% both at 5 hrs and 18 hrs. Identification accuracy of the 12 ATCC strains was 8/12 (66.6%) after 5 hrs and 12/12 (100%) after 18 hrs.