P. Maussion, M. Grandpierre, J. Faucher, J. Hapiot
{"title":"基于正弦波跟踪的非线性负载单相PWM逆变器瞬时反馈控制","authors":"P. Maussion, M. Grandpierre, J. Faucher, J. Hapiot","doi":"10.1109/IECON.1989.69623","DOIUrl":null,"url":null,"abstract":"The authors propose a novel method for the instantaneous digital control of a PWM (pulse-width modulated) inverter used in an uninterruptible power supply. The output voltage is compared to a sinusoidal reference at each sampling instant to compute in real time through a digital controller the pulse width of the same interval. The closed-loop digital feedback eliminates the steady-state error of the output voltage with a very short computation time. This strategy is verified through computer simulations and provides a very fast compensation of disturbances caused by nonlinear loads, such as rectifiers and triac loads, with low total harmonic distortion and fundamental control.<<ETX>>","PeriodicalId":384081,"journal":{"name":"15th Annual Conference of IEEE Industrial Electronics Society","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"36","resultStr":"{\"title\":\"Instantaneous feedback control of a single-phase PWM inverter with nonlinear loads by sine wave tracking\",\"authors\":\"P. Maussion, M. Grandpierre, J. Faucher, J. Hapiot\",\"doi\":\"10.1109/IECON.1989.69623\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors propose a novel method for the instantaneous digital control of a PWM (pulse-width modulated) inverter used in an uninterruptible power supply. The output voltage is compared to a sinusoidal reference at each sampling instant to compute in real time through a digital controller the pulse width of the same interval. The closed-loop digital feedback eliminates the steady-state error of the output voltage with a very short computation time. This strategy is verified through computer simulations and provides a very fast compensation of disturbances caused by nonlinear loads, such as rectifiers and triac loads, with low total harmonic distortion and fundamental control.<<ETX>>\",\"PeriodicalId\":384081,\"journal\":{\"name\":\"15th Annual Conference of IEEE Industrial Electronics Society\",\"volume\":\"96 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"36\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"15th Annual Conference of IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.1989.69623\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"15th Annual Conference of IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1989.69623","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Instantaneous feedback control of a single-phase PWM inverter with nonlinear loads by sine wave tracking
The authors propose a novel method for the instantaneous digital control of a PWM (pulse-width modulated) inverter used in an uninterruptible power supply. The output voltage is compared to a sinusoidal reference at each sampling instant to compute in real time through a digital controller the pulse width of the same interval. The closed-loop digital feedback eliminates the steady-state error of the output voltage with a very short computation time. This strategy is verified through computer simulations and provides a very fast compensation of disturbances caused by nonlinear loads, such as rectifiers and triac loads, with low total harmonic distortion and fundamental control.<>