{"title":"海洋平台谐波畸变的计算与测量","authors":"R. Morrison, B. Byfield, J.C.W. Corcoran","doi":"10.1109/ICHPS.1992.559000","DOIUrl":null,"url":null,"abstract":"This paper describes a series of harmonic calculations to predict the voltage distortion on an offshore oil production platform following the installation of variable frequency drives. A series of field tests is also described which provided measured values to compare with those calculated. I t is concluded that the calculation technique is accurate providing adequate information i s available to describe the converlor loading and the operating pattern. Both calculated and measured rcsults demonstrate the advantageous feature that harmonic voltage distortion does not increase linearly with converlor loading.","PeriodicalId":438464,"journal":{"name":"ICHPS V International Conference on Harmonics in Power Systems.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Calculation And Measurement Of Harmonic Distortion On Offshore Platforms\",\"authors\":\"R. Morrison, B. Byfield, J.C.W. Corcoran\",\"doi\":\"10.1109/ICHPS.1992.559000\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a series of harmonic calculations to predict the voltage distortion on an offshore oil production platform following the installation of variable frequency drives. A series of field tests is also described which provided measured values to compare with those calculated. I t is concluded that the calculation technique is accurate providing adequate information i s available to describe the converlor loading and the operating pattern. Both calculated and measured rcsults demonstrate the advantageous feature that harmonic voltage distortion does not increase linearly with converlor loading.\",\"PeriodicalId\":438464,\"journal\":{\"name\":\"ICHPS V International Conference on Harmonics in Power Systems.\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ICHPS V International Conference on Harmonics in Power Systems.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHPS.1992.559000\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICHPS V International Conference on Harmonics in Power Systems.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHPS.1992.559000","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Calculation And Measurement Of Harmonic Distortion On Offshore Platforms
This paper describes a series of harmonic calculations to predict the voltage distortion on an offshore oil production platform following the installation of variable frequency drives. A series of field tests is also described which provided measured values to compare with those calculated. I t is concluded that the calculation technique is accurate providing adequate information i s available to describe the converlor loading and the operating pattern. Both calculated and measured rcsults demonstrate the advantageous feature that harmonic voltage distortion does not increase linearly with converlor loading.