{"title":"在新北塘黎明口附近的一层土壤中,我们的凝胶粒和地化学应用程序进行了剪切处理","authors":"Aldianti Rizki Musdalifah Hutagalung, Usman Malik","doi":"10.31258/jkfi.18.2.159-166","DOIUrl":null,"url":null,"abstract":"Leachate is the result of degradation of filter, especially in location where the final management (TPA) can seep into the soil to contaminate groundwater sources. This research has been conducted geoelectric resistivity measurement to identify the presence of leachate seepage and spread around the landfill. Research conducted around TPA Muara Fajar Pekanbaru using Dipole-Dipole configuration on two tracks with a track length of 133 meters and 100 meters. The measurement data is then inverted using Res2Dinv software to produce a 2D resistivity profile. The analysis results show on line 1 there is leachate distribution at a depth of 8.86 meters, whereas on line 2 there is no leachate distribution. In addition, the leachate sample test results using the geochemical method showed that the leachate at TPA Muara Fajar Pekanbaru did not meet the leachate quality standard. The results of the sample test for the quality of well water from residents around the TPA are still in accordance with the quality of clean water, because leachate seepage has not reached the residential area.","PeriodicalId":403286,"journal":{"name":"Komunikasi Fisika Indonesia","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"APLIKASI METODE GEOLISTRIK DIPOLE-DIPOLE DAN GEOKIMIA DALAM PENENTUAN REMBESAN LINDI PADA LAPISAN TANAH DI SEKITAR TPA MUARA FAJAR PEKANBARU\",\"authors\":\"Aldianti Rizki Musdalifah Hutagalung, Usman Malik\",\"doi\":\"10.31258/jkfi.18.2.159-166\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Leachate is the result of degradation of filter, especially in location where the final management (TPA) can seep into the soil to contaminate groundwater sources. This research has been conducted geoelectric resistivity measurement to identify the presence of leachate seepage and spread around the landfill. Research conducted around TPA Muara Fajar Pekanbaru using Dipole-Dipole configuration on two tracks with a track length of 133 meters and 100 meters. The measurement data is then inverted using Res2Dinv software to produce a 2D resistivity profile. The analysis results show on line 1 there is leachate distribution at a depth of 8.86 meters, whereas on line 2 there is no leachate distribution. In addition, the leachate sample test results using the geochemical method showed that the leachate at TPA Muara Fajar Pekanbaru did not meet the leachate quality standard. The results of the sample test for the quality of well water from residents around the TPA are still in accordance with the quality of clean water, because leachate seepage has not reached the residential area.\",\"PeriodicalId\":403286,\"journal\":{\"name\":\"Komunikasi Fisika Indonesia\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Komunikasi Fisika Indonesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31258/jkfi.18.2.159-166\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Komunikasi Fisika Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31258/jkfi.18.2.159-166","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
渗滤液是过滤器降解的结果,特别是在最终管理(TPA)可能渗入土壤污染地下水资源的地方。本研究进行了地电阻率测量,以确定垃圾填埋场周围是否存在渗滤液渗漏和扩散。在TPA Muara Fajar Pekanbaru周围进行的研究使用了偶极子-偶极子配置,轨道长度为133米和100米。然后使用Res2Dinv软件对测量数据进行反演,生成二维电阻率剖面。分析结果表明,1号线在8.86 m深度处有渗滤液分布,2号线没有渗滤液分布。此外,利用地球化学方法进行的渗滤液样品检测结果表明,TPA Muara Fajar Pekanbaru渗滤液不符合渗滤液质量标准。对TPA周边居民的井水水质抽样检测结果仍符合净水水质,因为渗滤液尚未渗透到居民区。
APLIKASI METODE GEOLISTRIK DIPOLE-DIPOLE DAN GEOKIMIA DALAM PENENTUAN REMBESAN LINDI PADA LAPISAN TANAH DI SEKITAR TPA MUARA FAJAR PEKANBARU
Leachate is the result of degradation of filter, especially in location where the final management (TPA) can seep into the soil to contaminate groundwater sources. This research has been conducted geoelectric resistivity measurement to identify the presence of leachate seepage and spread around the landfill. Research conducted around TPA Muara Fajar Pekanbaru using Dipole-Dipole configuration on two tracks with a track length of 133 meters and 100 meters. The measurement data is then inverted using Res2Dinv software to produce a 2D resistivity profile. The analysis results show on line 1 there is leachate distribution at a depth of 8.86 meters, whereas on line 2 there is no leachate distribution. In addition, the leachate sample test results using the geochemical method showed that the leachate at TPA Muara Fajar Pekanbaru did not meet the leachate quality standard. The results of the sample test for the quality of well water from residents around the TPA are still in accordance with the quality of clean water, because leachate seepage has not reached the residential area.