{"title":"[尿中β - n -乙酰氨基葡萄糖酶测定新方法的多中心评价结果]。","authors":"G Klein","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We report on the results of a multicentric evaluation of a new kinetic method for the determination of beta-N-acetylglucosaminidase. Main topics of investigation were imprecision, recovery in controls with interlaboratory survey, measuring range, calibration stability, method comparisons using native urine and interferences. Distinct advantages in practicability and interlaboratory transferability compared to the introduced methods were observed. The new method fulfills the conditions to be adapted as routine method in the quantitative photometric analysis of urine.</p>","PeriodicalId":76822,"journal":{"name":"Wiener klinische Wochenschrift. Supplementum","volume":"189 ","pages":"31-8"},"PeriodicalIF":0.0000,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Results of the multicenter evaluation of a new test for measuring beta-N-acetylglucosaminidase in urine].\",\"authors\":\"G Klein\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We report on the results of a multicentric evaluation of a new kinetic method for the determination of beta-N-acetylglucosaminidase. Main topics of investigation were imprecision, recovery in controls with interlaboratory survey, measuring range, calibration stability, method comparisons using native urine and interferences. Distinct advantages in practicability and interlaboratory transferability compared to the introduced methods were observed. The new method fulfills the conditions to be adapted as routine method in the quantitative photometric analysis of urine.</p>\",\"PeriodicalId\":76822,\"journal\":{\"name\":\"Wiener klinische Wochenschrift. Supplementum\",\"volume\":\"189 \",\"pages\":\"31-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wiener klinische Wochenschrift. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wiener klinische Wochenschrift. Supplementum","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
我们报道了一种测定β - n -乙酰氨基葡萄糖酶的新动力学方法的多中心评价结果。调查的主要主题是不精确性、实验室间调查的对照回收率、测量范围、校准稳定性、使用天然尿液的方法比较和干扰。与引入的方法相比,在实用性和实验室间可转移性方面具有明显的优势。新方法满足了作为常规方法进行尿液定量光度分析的条件。
[Results of the multicenter evaluation of a new test for measuring beta-N-acetylglucosaminidase in urine].
We report on the results of a multicentric evaluation of a new kinetic method for the determination of beta-N-acetylglucosaminidase. Main topics of investigation were imprecision, recovery in controls with interlaboratory survey, measuring range, calibration stability, method comparisons using native urine and interferences. Distinct advantages in practicability and interlaboratory transferability compared to the introduced methods were observed. The new method fulfills the conditions to be adapted as routine method in the quantitative photometric analysis of urine.