矿物油、合成油和天然酯油在雷击电压下流光现象的比较研究

V. Dang, A. Beroual, C. Perrier
{"title":"矿物油、合成油和天然酯油在雷击电压下流光现象的比较研究","authors":"V. Dang, A. Beroual, C. Perrier","doi":"10.1109/ICHVE.2010.5640765","DOIUrl":null,"url":null,"abstract":"This paper presents the experimental results of a comparative study of mineral oils, synthetic ester oil and natural ester oils (vegetable oils) issued from different origins through the analyse of the initiation threshold voltage of streamers, their pattern and their stopping length (final length) Lf as well as the associated current and electrical charge, in a point - plane electrode arrangement submitted to a lightning impulse voltage (1.2/50 µs). It's shown that the streamers are filamentary in the different tested oils whatever the polarity of voltage. Lf is longer when the point is positive than when it's negative whatever the oil. It's is generally longer in ester oils (natural and synthetic) than in some mineral oils. When the point is negative, Lf can be ten times higher in ester oils than in mineral ones. Basing on the stopping length of streamers, the positive polarity appears as the most unfavorable one for industrial applications and the dielectric strength of mineral oils we tested are generally better (in the considered experimental conditions) than that of ester oils.","PeriodicalId":287425,"journal":{"name":"2010 International Conference on High Voltage Engineering and Application","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":"{\"title\":\"Comparative study of streamer phenomena in mineral, synthetic and natural ester oils under lightning impulse voltage\",\"authors\":\"V. Dang, A. Beroual, C. Perrier\",\"doi\":\"10.1109/ICHVE.2010.5640765\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the experimental results of a comparative study of mineral oils, synthetic ester oil and natural ester oils (vegetable oils) issued from different origins through the analyse of the initiation threshold voltage of streamers, their pattern and their stopping length (final length) Lf as well as the associated current and electrical charge, in a point - plane electrode arrangement submitted to a lightning impulse voltage (1.2/50 µs). It's shown that the streamers are filamentary in the different tested oils whatever the polarity of voltage. Lf is longer when the point is positive than when it's negative whatever the oil. It's is generally longer in ester oils (natural and synthetic) than in some mineral oils. When the point is negative, Lf can be ten times higher in ester oils than in mineral ones. Basing on the stopping length of streamers, the positive polarity appears as the most unfavorable one for industrial applications and the dielectric strength of mineral oils we tested are generally better (in the considered experimental conditions) than that of ester oils.\",\"PeriodicalId\":287425,\"journal\":{\"name\":\"2010 International Conference on High Voltage Engineering and Application\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"30\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on High Voltage Engineering and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE.2010.5640765\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2010.5640765","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30

摘要

本文对矿物油、合成酯油和不同来源的天然酯油(植物油)进行了对比研究,分析了在点平面电极布置下,在雷电冲击电压(1.2/50µs)下,飘带的起始阈值电压、形态、停止长度(最终长度)Lf以及相关电流和电荷。结果表明,在不同的测试油中,无论电压的极性如何,飘带都是丝状的。当这个点为正的时候比当它为负的时候更长,不管油是多少。酯类油(天然的和合成的)通常比矿物油长。当该点为负时,酯类油的f值比矿物油高10倍。根据拖缆的停止长度,正极性似乎是工业应用中最不利的极性,我们测试的矿物油的介电强度通常比酯油好(在考虑的实验条件下)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative study of streamer phenomena in mineral, synthetic and natural ester oils under lightning impulse voltage
This paper presents the experimental results of a comparative study of mineral oils, synthetic ester oil and natural ester oils (vegetable oils) issued from different origins through the analyse of the initiation threshold voltage of streamers, their pattern and their stopping length (final length) Lf as well as the associated current and electrical charge, in a point - plane electrode arrangement submitted to a lightning impulse voltage (1.2/50 µs). It's shown that the streamers are filamentary in the different tested oils whatever the polarity of voltage. Lf is longer when the point is positive than when it's negative whatever the oil. It's is generally longer in ester oils (natural and synthetic) than in some mineral oils. When the point is negative, Lf can be ten times higher in ester oils than in mineral ones. Basing on the stopping length of streamers, the positive polarity appears as the most unfavorable one for industrial applications and the dielectric strength of mineral oils we tested are generally better (in the considered experimental conditions) than that of ester oils.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Non-destructive test methods for hollow-core composite insulators Investigation of the effect of conductor temperature on AC power line corona Field characteristics and dielectric tests on an IGBT module plate Ultra wide band response of partial discharge test circuit The expert transformer monitoring system in substation structure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1