{"title":"电网不平衡故障下分布式发电系统PI和PR控制器分析","authors":"Ashish Ranjan Dash, B. Babu, K. Mohanty, R. Dubey","doi":"10.1109/ICPES.2011.6156688","DOIUrl":null,"url":null,"abstract":"It is the general trend to increase the electricity production using distributed power system (DPGS), which is based on renewable energy sources such as wind, solar, fuel cell etc. These systems are to be properly controlled in order to provide reliable power to the utility network. For that power electronics converters are used as an interfacing device between DPGS and utility network. In case of unbalanced fault, the major problem in distributed power generation system is the phase unbalance which causes the power quality problem along with grid instability. This paper discuses the implementation of two different controllers namely Proportional — integral (PI) and proportional resonant (PR) controllers in order to obtain the control of grid side converter during single phase to ground fault. The analysis includes the grid current harmonic distortion along with the variation of active and reactive power during the fault condition. The system is simulated using MATLAB software and simulation results demonstrate the effectiveness of both the controller.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"225 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":"{\"title\":\"Analysis of PI and PR controllers for distributed power generation system under unbalanced grid faults\",\"authors\":\"Ashish Ranjan Dash, B. Babu, K. Mohanty, R. Dubey\",\"doi\":\"10.1109/ICPES.2011.6156688\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is the general trend to increase the electricity production using distributed power system (DPGS), which is based on renewable energy sources such as wind, solar, fuel cell etc. These systems are to be properly controlled in order to provide reliable power to the utility network. For that power electronics converters are used as an interfacing device between DPGS and utility network. In case of unbalanced fault, the major problem in distributed power generation system is the phase unbalance which causes the power quality problem along with grid instability. This paper discuses the implementation of two different controllers namely Proportional — integral (PI) and proportional resonant (PR) controllers in order to obtain the control of grid side converter during single phase to ground fault. The analysis includes the grid current harmonic distortion along with the variation of active and reactive power during the fault condition. The system is simulated using MATLAB software and simulation results demonstrate the effectiveness of both the controller.\",\"PeriodicalId\":158903,\"journal\":{\"name\":\"2011 International Conference on Power and Energy Systems\",\"volume\":\"225 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"30\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Power and Energy Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPES.2011.6156688\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPES.2011.6156688","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of PI and PR controllers for distributed power generation system under unbalanced grid faults
It is the general trend to increase the electricity production using distributed power system (DPGS), which is based on renewable energy sources such as wind, solar, fuel cell etc. These systems are to be properly controlled in order to provide reliable power to the utility network. For that power electronics converters are used as an interfacing device between DPGS and utility network. In case of unbalanced fault, the major problem in distributed power generation system is the phase unbalance which causes the power quality problem along with grid instability. This paper discuses the implementation of two different controllers namely Proportional — integral (PI) and proportional resonant (PR) controllers in order to obtain the control of grid side converter during single phase to ground fault. The analysis includes the grid current harmonic distortion along with the variation of active and reactive power during the fault condition. The system is simulated using MATLAB software and simulation results demonstrate the effectiveness of both the controller.