{"title":"曝光因素对辐射图像质量的影响","authors":"Eif Sparzinanda, Nehru Nehru, Nurhidayah Nurhidayah","doi":"10.22437/jop.v3i1.4428","DOIUrl":null,"url":null,"abstract":"The research on the influence of exposure factor on radiographic image quality has been conducted. This research uses phantom, water in plastic container as human substitute with focus film distance (FFD) 100 cm and broad field of irradiation 15 cm × 15 cm. The exposure conditions are given by exposure factors including variations in tube voltages of 60 kV, 65 kV, 70 kV, 75 kV, 80 kV called standard techniques or routine voltage techniques and the time flow is as big as 20 mAs, 25 mAs and 30 mAs. The results showed that the image quality will decrease with the use of current and time high. Image quality can be seen on gray-level histogram using java Image-J Basics version 1.38 software to get optimum value from exposure factor on image quality.","PeriodicalId":415382,"journal":{"name":"JOURNAL ONLINE OF PHYSICS","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"PENGARUH FAKTOR EKSPOSI TERHADAP KUALITAS CITRA RADIOGRAFI\",\"authors\":\"Eif Sparzinanda, Nehru Nehru, Nurhidayah Nurhidayah\",\"doi\":\"10.22437/jop.v3i1.4428\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The research on the influence of exposure factor on radiographic image quality has been conducted. This research uses phantom, water in plastic container as human substitute with focus film distance (FFD) 100 cm and broad field of irradiation 15 cm × 15 cm. The exposure conditions are given by exposure factors including variations in tube voltages of 60 kV, 65 kV, 70 kV, 75 kV, 80 kV called standard techniques or routine voltage techniques and the time flow is as big as 20 mAs, 25 mAs and 30 mAs. The results showed that the image quality will decrease with the use of current and time high. Image quality can be seen on gray-level histogram using java Image-J Basics version 1.38 software to get optimum value from exposure factor on image quality.\",\"PeriodicalId\":415382,\"journal\":{\"name\":\"JOURNAL ONLINE OF PHYSICS\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JOURNAL ONLINE OF PHYSICS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22437/jop.v3i1.4428\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JOURNAL ONLINE OF PHYSICS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22437/jop.v3i1.4428","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
摘要
对曝光系数对射线成像质量的影响进行了研究。本研究采用幻影、塑料容器中的水作为人体替代物,聚焦膜距离(FFD)为100 cm,宽照射场为15 cm × 15 cm。暴露条件由暴露因素给出,包括60千伏、65千伏、70千伏、75千伏、80千伏的管电压变化,称为标准技术或常规电压技术,时间流量可达20、25、30毫安。结果表明,随着使用电流和时间的增加,图像质量会下降。使用java Image- j Basics version 1.38软件在灰度直方图上可以看到图像质量,从曝光系数中得到图像质量的最优值。
PENGARUH FAKTOR EKSPOSI TERHADAP KUALITAS CITRA RADIOGRAFI
The research on the influence of exposure factor on radiographic image quality has been conducted. This research uses phantom, water in plastic container as human substitute with focus film distance (FFD) 100 cm and broad field of irradiation 15 cm × 15 cm. The exposure conditions are given by exposure factors including variations in tube voltages of 60 kV, 65 kV, 70 kV, 75 kV, 80 kV called standard techniques or routine voltage techniques and the time flow is as big as 20 mAs, 25 mAs and 30 mAs. The results showed that the image quality will decrease with the use of current and time high. Image quality can be seen on gray-level histogram using java Image-J Basics version 1.38 software to get optimum value from exposure factor on image quality.