曝光因素对辐射图像质量的影响

Eif Sparzinanda, Nehru Nehru, Nurhidayah Nurhidayah
{"title":"曝光因素对辐射图像质量的影响","authors":"Eif Sparzinanda, Nehru Nehru, Nurhidayah Nurhidayah","doi":"10.22437/jop.v3i1.4428","DOIUrl":null,"url":null,"abstract":"The research  on the influence of exposure factor on radiographic image quality has been conducted. This research uses phantom, water in plastic container as human substitute with focus film distance (FFD) 100 cm and broad field of irradiation 15 cm × 15 cm. The exposure conditions are given by exposure factors including variations in tube voltages of 60 kV, 65 kV, 70 kV, 75 kV, 80 kV called standard techniques or routine voltage techniques and the time flow is as big as 20 mAs, 25 mAs and 30 mAs. The results showed that the image quality will decrease with the use of current and time high. Image quality can be seen on gray-level histogram using java Image-J Basics version 1.38 software to get optimum value from exposure factor on image quality.","PeriodicalId":415382,"journal":{"name":"JOURNAL ONLINE OF PHYSICS","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"PENGARUH FAKTOR EKSPOSI TERHADAP KUALITAS CITRA RADIOGRAFI\",\"authors\":\"Eif Sparzinanda, Nehru Nehru, Nurhidayah Nurhidayah\",\"doi\":\"10.22437/jop.v3i1.4428\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The research  on the influence of exposure factor on radiographic image quality has been conducted. This research uses phantom, water in plastic container as human substitute with focus film distance (FFD) 100 cm and broad field of irradiation 15 cm × 15 cm. The exposure conditions are given by exposure factors including variations in tube voltages of 60 kV, 65 kV, 70 kV, 75 kV, 80 kV called standard techniques or routine voltage techniques and the time flow is as big as 20 mAs, 25 mAs and 30 mAs. The results showed that the image quality will decrease with the use of current and time high. Image quality can be seen on gray-level histogram using java Image-J Basics version 1.38 software to get optimum value from exposure factor on image quality.\",\"PeriodicalId\":415382,\"journal\":{\"name\":\"JOURNAL ONLINE OF PHYSICS\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JOURNAL ONLINE OF PHYSICS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22437/jop.v3i1.4428\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JOURNAL ONLINE OF PHYSICS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22437/jop.v3i1.4428","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

对曝光系数对射线成像质量的影响进行了研究。本研究采用幻影、塑料容器中的水作为人体替代物,聚焦膜距离(FFD)为100 cm,宽照射场为15 cm × 15 cm。暴露条件由暴露因素给出,包括60千伏、65千伏、70千伏、75千伏、80千伏的管电压变化,称为标准技术或常规电压技术,时间流量可达20、25、30毫安。结果表明,随着使用电流和时间的增加,图像质量会下降。使用java Image- j Basics version 1.38软件在灰度直方图上可以看到图像质量,从曝光系数中得到图像质量的最优值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
PENGARUH FAKTOR EKSPOSI TERHADAP KUALITAS CITRA RADIOGRAFI
The research  on the influence of exposure factor on radiographic image quality has been conducted. This research uses phantom, water in plastic container as human substitute with focus film distance (FFD) 100 cm and broad field of irradiation 15 cm × 15 cm. The exposure conditions are given by exposure factors including variations in tube voltages of 60 kV, 65 kV, 70 kV, 75 kV, 80 kV called standard techniques or routine voltage techniques and the time flow is as big as 20 mAs, 25 mAs and 30 mAs. The results showed that the image quality will decrease with the use of current and time high. Image quality can be seen on gray-level histogram using java Image-J Basics version 1.38 software to get optimum value from exposure factor on image quality.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
STUDY ON DOPPLER EFFECT BASED ON FREQUENCY AND VELOCITY OF SOUND SOURCE IN THE WATERS PENGEMBANGAN ALAT UKUR KEMATANGAN KOMPOS BERBASIS ARDUINO ATMEGA328 KARAKTERISASI NATURAL HIDROKSIAPATIT DARI TULANG IKAN LELE (Calarias batracus) ANALYSIS OF ACTIVATED CARBON (PETUNG BAMBOO)/LATEX COMPOSITE AS X-BAND WAVE-ABSORBING MATERIAL ANALISIS SIFAT MEKANIK LIST GYPSUM BERBASIS SERAT RAMI
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1