视神经头耐压能力的标准化测定。

R Stodtmeister, I Wilmanns, L E Pillunat, C Uhl
{"title":"视神经头耐压能力的标准化测定。","authors":"R Stodtmeister,&nbsp;I Wilmanns,&nbsp;L E Pillunat,&nbsp;C Uhl","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The early diagnosis of glaucoma relies on the detection of manifest damage in present-day clinical practice. The reason for such damage in glaucoma may be seen in the breakdown of the autoregulation of the circulation in the optic nerve head. This autoregulation can be assessed by the pressure tolerance test devised by ourselves which may detect glaucoma before manifest damage can occur. We demonstrate a standardized method in which the test procedure is controlled by a computer. In particular, the time course of the examination which is of crucial importance is exactly defined. The method is no more difficult to apply than automatic perimetry. We describe six examinations in seven subjects each. The results are analyzed by the estimation of variance components. The intraocular pressure shows an intraclass correlation of 0.41 and the critical pressure an intraclass correlation of 0.27. The intraindividual variability of critical pressure is mainly due to the widely known variability of intraocular pressure. The autoregulation behavior shows a very good constancy, which makes the test clinically useful in the differential diagnosis of glaucoma.</p>","PeriodicalId":12437,"journal":{"name":"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft","volume":"88 1","pages":"99-104"},"PeriodicalIF":0.0000,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Standardized determination of pressure tolerance of the optic nerve head].\",\"authors\":\"R Stodtmeister,&nbsp;I Wilmanns,&nbsp;L E Pillunat,&nbsp;C Uhl\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The early diagnosis of glaucoma relies on the detection of manifest damage in present-day clinical practice. The reason for such damage in glaucoma may be seen in the breakdown of the autoregulation of the circulation in the optic nerve head. This autoregulation can be assessed by the pressure tolerance test devised by ourselves which may detect glaucoma before manifest damage can occur. We demonstrate a standardized method in which the test procedure is controlled by a computer. In particular, the time course of the examination which is of crucial importance is exactly defined. The method is no more difficult to apply than automatic perimetry. We describe six examinations in seven subjects each. The results are analyzed by the estimation of variance components. The intraocular pressure shows an intraclass correlation of 0.41 and the critical pressure an intraclass correlation of 0.27. The intraindividual variability of critical pressure is mainly due to the widely known variability of intraocular pressure. The autoregulation behavior shows a very good constancy, which makes the test clinically useful in the differential diagnosis of glaucoma.</p>\",\"PeriodicalId\":12437,\"journal\":{\"name\":\"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft\",\"volume\":\"88 1\",\"pages\":\"99-104\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

青光眼的早期诊断主要依赖于对明显损伤的检测。青光眼造成这种损害的原因可能是视神经头循环的自动调节功能被破坏。这种自动调节可以通过我们自己设计的耐压试验来评估,该试验可以在青光眼发生明显损害之前检测到。我们演示了一种标准化的方法,其中测试过程由计算机控制。特别是,考试的时间过程是至关重要的是精确定义。这种方法的应用并不比自动视距法困难。我们描述了七个科目的六个考试。通过方差分量的估计对结果进行分析。眼压的类内相关性为0.41,临界眼压的类内相关性为0.27。临界压的个体变异主要是由于众所周知的眼压变异。其自调节行为具有很好的稳定性,可用于青光眼的鉴别诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Standardized determination of pressure tolerance of the optic nerve head].

The early diagnosis of glaucoma relies on the detection of manifest damage in present-day clinical practice. The reason for such damage in glaucoma may be seen in the breakdown of the autoregulation of the circulation in the optic nerve head. This autoregulation can be assessed by the pressure tolerance test devised by ourselves which may detect glaucoma before manifest damage can occur. We demonstrate a standardized method in which the test procedure is controlled by a computer. In particular, the time course of the examination which is of crucial importance is exactly defined. The method is no more difficult to apply than automatic perimetry. We describe six examinations in seven subjects each. The results are analyzed by the estimation of variance components. The intraocular pressure shows an intraclass correlation of 0.41 and the critical pressure an intraclass correlation of 0.27. The intraindividual variability of critical pressure is mainly due to the widely known variability of intraocular pressure. The autoregulation behavior shows a very good constancy, which makes the test clinically useful in the differential diagnosis of glaucoma.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Thermoradiotherapy for Malignant Choroidal Melanoma: The Development of a New Microwave Hyperthermia System [Planimetric follow-up of cytomegalovirus retinitis treated with ganciclovir in patients with AIDS]. [Detection of HCMV-DNA in aqueous humor for diagnostic confirmation of viral retinitis]. [Herpes simplex virus retinitis. Role of the immune system in the animal experiment]. [Electro-ophthalmologic studies in HIV patients].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1