{"title":"马来西亚132kV架空线路雷电相关闪络调查","authors":"I. M. Rawi, Mohd Zainal Abidin Ab Kadir","doi":"10.1109/SIPDA.2015.7339293","DOIUrl":null,"url":null,"abstract":"The Transmission Division of Tenaga Nasional Berhad (TNB) manages and operates transmission system ranges from 66kV up to 500kV in Peninsular Malaysia. Being in tropical country with high keraunic level, system outages due to lightning strikes has become major issue each year. This paper present the findings of an investigation on a series of lightning-related flashovers which occurs on the 132kV Kuala Krai (KKRJ) to Gua Musang (GMSG) line in Malaysia. Lightning activities were recorded by Lightning Detection System (LDS) during the flashover occurrence and it was analyzed. Possible cause of failures which are related to Transmission Line Arrester (TLA) installation and Tower Footing Resistance (TFR) were explained to conclude the multiple numbers of tripouts on the line. Suggestions to increase the performance of the line are also discussed.","PeriodicalId":296478,"journal":{"name":"2015 International Symposium on Lightning Protection (XIII SIPDA)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Investigation on the 132kV overhead lines lightning-related flashovers in Malaysia\",\"authors\":\"I. M. Rawi, Mohd Zainal Abidin Ab Kadir\",\"doi\":\"10.1109/SIPDA.2015.7339293\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Transmission Division of Tenaga Nasional Berhad (TNB) manages and operates transmission system ranges from 66kV up to 500kV in Peninsular Malaysia. Being in tropical country with high keraunic level, system outages due to lightning strikes has become major issue each year. This paper present the findings of an investigation on a series of lightning-related flashovers which occurs on the 132kV Kuala Krai (KKRJ) to Gua Musang (GMSG) line in Malaysia. Lightning activities were recorded by Lightning Detection System (LDS) during the flashover occurrence and it was analyzed. Possible cause of failures which are related to Transmission Line Arrester (TLA) installation and Tower Footing Resistance (TFR) were explained to conclude the multiple numbers of tripouts on the line. Suggestions to increase the performance of the line are also discussed.\",\"PeriodicalId\":296478,\"journal\":{\"name\":\"2015 International Symposium on Lightning Protection (XIII SIPDA)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Symposium on Lightning Protection (XIII SIPDA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIPDA.2015.7339293\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Symposium on Lightning Protection (XIII SIPDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2015.7339293","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation on the 132kV overhead lines lightning-related flashovers in Malaysia
The Transmission Division of Tenaga Nasional Berhad (TNB) manages and operates transmission system ranges from 66kV up to 500kV in Peninsular Malaysia. Being in tropical country with high keraunic level, system outages due to lightning strikes has become major issue each year. This paper present the findings of an investigation on a series of lightning-related flashovers which occurs on the 132kV Kuala Krai (KKRJ) to Gua Musang (GMSG) line in Malaysia. Lightning activities were recorded by Lightning Detection System (LDS) during the flashover occurrence and it was analyzed. Possible cause of failures which are related to Transmission Line Arrester (TLA) installation and Tower Footing Resistance (TFR) were explained to conclude the multiple numbers of tripouts on the line. Suggestions to increase the performance of the line are also discussed.