采用离散时域控制方法实现单相功率因数校正电路的高性能控制

J. Rajagopalan, J.G. Cho, B. Cho, F. Lee
{"title":"采用离散时域控制方法实现单相功率因数校正电路的高性能控制","authors":"J. Rajagopalan, J.G. Cho, B. Cho, F. Lee","doi":"10.1109/APEC.1995.469089","DOIUrl":null,"url":null,"abstract":"A simple high performance discrete time domain control method of single-phase power factor correction (PFC) circuits is presented to improve the dynamic performance of the output voltage control loop. By adding only a sample and hold (S/H) in the outer voltage loop, the output voltage can be sensed without the 120 Hz ripple and accordingly, a high bandwidth output voltage loop can be designed without any input current distortions. Analysis and design steps are detailed. Simulation results are presented to verify that the performance has improved over a conventional voltage loop control method.<<ETX>>","PeriodicalId":335367,"journal":{"name":"Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"High performance control of single-phase power factor correction circuits using a discrete time domain control method\",\"authors\":\"J. Rajagopalan, J.G. Cho, B. Cho, F. Lee\",\"doi\":\"10.1109/APEC.1995.469089\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple high performance discrete time domain control method of single-phase power factor correction (PFC) circuits is presented to improve the dynamic performance of the output voltage control loop. By adding only a sample and hold (S/H) in the outer voltage loop, the output voltage can be sensed without the 120 Hz ripple and accordingly, a high bandwidth output voltage loop can be designed without any input current distortions. Analysis and design steps are detailed. Simulation results are presented to verify that the performance has improved over a conventional voltage loop control method.<<ETX>>\",\"PeriodicalId\":335367,\"journal\":{\"name\":\"Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.1995.469089\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.1995.469089","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

摘要

为了提高输出电压控制回路的动态性能,提出了一种简单、高性能的单相功率因数校正(PFC)离散时域控制方法。通过在外电压环中加入采样和保持(S/H),可以在没有120hz纹波的情况下检测输出电压,从而可以设计出没有任何输入电流畸变的高带宽输出电压环。详细介绍了分析和设计步骤。仿真结果表明,与传统的电压环控制方法相比,该方法的性能得到了改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High performance control of single-phase power factor correction circuits using a discrete time domain control method
A simple high performance discrete time domain control method of single-phase power factor correction (PFC) circuits is presented to improve the dynamic performance of the output voltage control loop. By adding only a sample and hold (S/H) in the outer voltage loop, the output voltage can be sensed without the 120 Hz ripple and accordingly, a high bandwidth output voltage loop can be designed without any input current distortions. Analysis and design steps are detailed. Simulation results are presented to verify that the performance has improved over a conventional voltage loop control method.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
0
期刊最新文献
Utility interface issues for line connected PWM voltage source converters: a comparative study A new secondary side post regulator (SSPR) PWM controller for multiple output power supplies Implementation of a speed sensor-less vector control of induction motor by reduced-order extended Kalman filter Self excited half-bridge series resonant parallel loaded fluorescent lamp electronic ballasts A simple tool for the selection of IGBTs for motor drives and UPSs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1