N. D. Ahmad, Ahmad Hafiz Mohd Hashim, N. Azis, M. Talib, K. A. Rezali, N. H. Nik Ali, J. Jasni, Kozako Masahiro, M. Jamil
{"title":"基于声发射法的精制漂白脱臭棕榈油局部放电定位","authors":"N. D. Ahmad, Ahmad Hafiz Mohd Hashim, N. Azis, M. Talib, K. A. Rezali, N. H. Nik Ali, J. Jasni, Kozako Masahiro, M. Jamil","doi":"10.1109/APL57308.2023.10181667","DOIUrl":null,"url":null,"abstract":"This paper examines the performance of partial discharge localization refined bleach deodorized palm oil (RBDPO) based on acoustic emission (AE) partial discharge (PD) method. The PD was initiated through a needle-plane electrodes configuration. The electrical PD was measured through Impedance Matching Circuit (IMC) whereby the AE PD signal was measured using AE sensor placed on the surface of the test tank. The time of arrival (TOA) was computed based on the electrical and AE PD signals. It is found that the PD count and maximum amplitude for RBDPO are lower than mineral oil. The PD in RBDPO can be located through TOA whereby the location error is lower than MO.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Partial Discharge Localization of Refined Bleached Deodorized Palm Oil (RBDPO) based on Acoustic Emission Method\",\"authors\":\"N. D. Ahmad, Ahmad Hafiz Mohd Hashim, N. Azis, M. Talib, K. A. Rezali, N. H. Nik Ali, J. Jasni, Kozako Masahiro, M. Jamil\",\"doi\":\"10.1109/APL57308.2023.10181667\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper examines the performance of partial discharge localization refined bleach deodorized palm oil (RBDPO) based on acoustic emission (AE) partial discharge (PD) method. The PD was initiated through a needle-plane electrodes configuration. The electrical PD was measured through Impedance Matching Circuit (IMC) whereby the AE PD signal was measured using AE sensor placed on the surface of the test tank. The time of arrival (TOA) was computed based on the electrical and AE PD signals. It is found that the PD count and maximum amplitude for RBDPO are lower than mineral oil. The PD in RBDPO can be located through TOA whereby the location error is lower than MO.\",\"PeriodicalId\":371726,\"journal\":{\"name\":\"2023 12th Asia-Pacific International Conference on Lightning (APL)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 12th Asia-Pacific International Conference on Lightning (APL)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APL57308.2023.10181667\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 12th Asia-Pacific International Conference on Lightning (APL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APL57308.2023.10181667","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Partial Discharge Localization of Refined Bleached Deodorized Palm Oil (RBDPO) based on Acoustic Emission Method
This paper examines the performance of partial discharge localization refined bleach deodorized palm oil (RBDPO) based on acoustic emission (AE) partial discharge (PD) method. The PD was initiated through a needle-plane electrodes configuration. The electrical PD was measured through Impedance Matching Circuit (IMC) whereby the AE PD signal was measured using AE sensor placed on the surface of the test tank. The time of arrival (TOA) was computed based on the electrical and AE PD signals. It is found that the PD count and maximum amplitude for RBDPO are lower than mineral oil. The PD in RBDPO can be located through TOA whereby the location error is lower than MO.