{"title":"一种方便的四端口反射计校准程序:在六端口反射计和外差网络分析仪上的应用","authors":"S. Abou chahine, B. Huyart, L. Jallet","doi":"10.1109/NRSC.2000.838844","DOIUrl":null,"url":null,"abstract":"This paper presents a millimeter-wave six-port reflectometer in the W-frequency band (75-110 GHz). A convenient calibration technique requiring two standards is described. The measurement performance of this method is compared with the results of a dual six-port network analyzer using the LRL calibration procedure. Moreover, characterization of some components by the heterodyne network analyzer in the reflection mode using this technique and other calibration methods are presented.","PeriodicalId":211510,"journal":{"name":"Proceedings of the Seventeenth National Radio Science Conference. 17th NRSC'2000 (IEEE Cat. No.00EX396)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2000-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A convenient calibration procedure of four-port reflectometers: application on six-port reflectometer and heterodyne network analyzer\",\"authors\":\"S. Abou chahine, B. Huyart, L. Jallet\",\"doi\":\"10.1109/NRSC.2000.838844\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a millimeter-wave six-port reflectometer in the W-frequency band (75-110 GHz). A convenient calibration technique requiring two standards is described. The measurement performance of this method is compared with the results of a dual six-port network analyzer using the LRL calibration procedure. Moreover, characterization of some components by the heterodyne network analyzer in the reflection mode using this technique and other calibration methods are presented.\",\"PeriodicalId\":211510,\"journal\":{\"name\":\"Proceedings of the Seventeenth National Radio Science Conference. 17th NRSC'2000 (IEEE Cat. No.00EX396)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-02-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Seventeenth National Radio Science Conference. 17th NRSC'2000 (IEEE Cat. No.00EX396)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NRSC.2000.838844\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Seventeenth National Radio Science Conference. 17th NRSC'2000 (IEEE Cat. No.00EX396)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NRSC.2000.838844","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A convenient calibration procedure of four-port reflectometers: application on six-port reflectometer and heterodyne network analyzer
This paper presents a millimeter-wave six-port reflectometer in the W-frequency band (75-110 GHz). A convenient calibration technique requiring two standards is described. The measurement performance of this method is compared with the results of a dual six-port network analyzer using the LRL calibration procedure. Moreover, characterization of some components by the heterodyne network analyzer in the reflection mode using this technique and other calibration methods are presented.