{"title":"传输系统功率摆动检测的应用指南","authors":"Joe Mooney, Normann Fischer","doi":"10.1109/PSAMP.2006.285385","DOIUrl":null,"url":null,"abstract":"Power swing detection on transmission systems is becoming more critical. Traditionally, setting relays for power swing blocking (PSB) or power swing tripping applications has been very complex and time consuming. In many cases, the settings are not correct, which is discovered when the relay operates incorrectly. This paper provides the reader with practical setting and application guidelines for traditional impedance-based PSB schemes. It shows how to set a PSB scheme without stability studies. Highlighted are some problem areas when setting and applying power swing detection elements. Application of these setting guidelines will be demonstrated using a power system modeled on a real-time digital simulator","PeriodicalId":125883,"journal":{"name":"59th Annual Conference for Protective Relay Engineers, 2006.","volume":"63 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"72","resultStr":"{\"title\":\"Application guidelines for power swing detection on transmission systems\",\"authors\":\"Joe Mooney, Normann Fischer\",\"doi\":\"10.1109/PSAMP.2006.285385\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power swing detection on transmission systems is becoming more critical. Traditionally, setting relays for power swing blocking (PSB) or power swing tripping applications has been very complex and time consuming. In many cases, the settings are not correct, which is discovered when the relay operates incorrectly. This paper provides the reader with practical setting and application guidelines for traditional impedance-based PSB schemes. It shows how to set a PSB scheme without stability studies. Highlighted are some problem areas when setting and applying power swing detection elements. Application of these setting guidelines will be demonstrated using a power system modeled on a real-time digital simulator\",\"PeriodicalId\":125883,\"journal\":{\"name\":\"59th Annual Conference for Protective Relay Engineers, 2006.\",\"volume\":\"63 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-03-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"72\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"59th Annual Conference for Protective Relay Engineers, 2006.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PSAMP.2006.285385\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"59th Annual Conference for Protective Relay Engineers, 2006.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PSAMP.2006.285385","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application guidelines for power swing detection on transmission systems
Power swing detection on transmission systems is becoming more critical. Traditionally, setting relays for power swing blocking (PSB) or power swing tripping applications has been very complex and time consuming. In many cases, the settings are not correct, which is discovered when the relay operates incorrectly. This paper provides the reader with practical setting and application guidelines for traditional impedance-based PSB schemes. It shows how to set a PSB scheme without stability studies. Highlighted are some problem areas when setting and applying power swing detection elements. Application of these setting guidelines will be demonstrated using a power system modeled on a real-time digital simulator