{"title":"交直流混地网绝缘电阻的测量与自动监测","authors":"Anh Cam Thi Kim, Giang Truong Nguyen, S. T. Nguyen, Q. Nguyen","doi":"10.46326/jmes.2022.63(2).08","DOIUrl":null,"url":null,"abstract":"Where the danger of electric shock is high, for example underground mines or medical equipment directly connected to a patient, special ungrounded power systems (unearthed networks) may be used to minimize possible leakage current to the ground. In mixed unearthed networks (AC/DC-IT) comprising alternating and direct current circuits, AC part of system is connected with DC part through rectifyer valves. Commutation of the valves causes cyclic variation of configuration of the entire galvanically connected network. A distinct feature of AC/DC-IT systems is that voltages between all points of AC side and ground may have mean value different from zero. This characteristic parameter can be used as a signal to determine fault and position to ground or decrease in insulation resistance. However, it also affects the results of the network equivalent insulation resistance measurements when a DC source is used to check insulation. The paper presents a solution to eliminate this effect and proposes a device model to measure and monitor insulation resistance. The results of this study can be applied in the design and manufacture of automatic resistance measuring and monitoring devices for AC/DC mixed unearthed networks.","PeriodicalId":170167,"journal":{"name":"Journal of Mining and Earth Sciences","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement and automatic monitoring insulation resistance of AC/DC mixed unearthed networks\",\"authors\":\"Anh Cam Thi Kim, Giang Truong Nguyen, S. T. Nguyen, Q. Nguyen\",\"doi\":\"10.46326/jmes.2022.63(2).08\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Where the danger of electric shock is high, for example underground mines or medical equipment directly connected to a patient, special ungrounded power systems (unearthed networks) may be used to minimize possible leakage current to the ground. In mixed unearthed networks (AC/DC-IT) comprising alternating and direct current circuits, AC part of system is connected with DC part through rectifyer valves. Commutation of the valves causes cyclic variation of configuration of the entire galvanically connected network. A distinct feature of AC/DC-IT systems is that voltages between all points of AC side and ground may have mean value different from zero. This characteristic parameter can be used as a signal to determine fault and position to ground or decrease in insulation resistance. However, it also affects the results of the network equivalent insulation resistance measurements when a DC source is used to check insulation. The paper presents a solution to eliminate this effect and proposes a device model to measure and monitor insulation resistance. The results of this study can be applied in the design and manufacture of automatic resistance measuring and monitoring devices for AC/DC mixed unearthed networks.\",\"PeriodicalId\":170167,\"journal\":{\"name\":\"Journal of Mining and Earth Sciences\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mining and Earth Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46326/jmes.2022.63(2).08\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mining and Earth Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46326/jmes.2022.63(2).08","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在触电危险高的地方,例如地下矿井或直接与病人相连的医疗设备,可以使用特殊的不接地电力系统(地下电网),以尽量减少可能漏电到地面的电流。在交直流混合地下网络(AC/DC- it)中,系统的交流部分通过整流阀与直流部分连接。阀门的换向引起整个电连接网络结构的循环变化。交流/直流- it系统的一个显著特征是交流侧和地之间的所有点之间的电压可能具有不同于零的平均值。该特性参数可作为确定故障和接地位置或降低绝缘电阻的信号。但是,当使用直流电源检查绝缘时,它也会影响网络等效绝缘电阻测量的结果。本文提出了消除这种影响的解决方案,并提出了一种测量和监测绝缘电阻的器件模型。研究结果可用于交直流混合地下网络电阻自动测量与监测装置的设计与制造。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement and automatic monitoring insulation resistance of AC/DC mixed unearthed networks
Where the danger of electric shock is high, for example underground mines or medical equipment directly connected to a patient, special ungrounded power systems (unearthed networks) may be used to minimize possible leakage current to the ground. In mixed unearthed networks (AC/DC-IT) comprising alternating and direct current circuits, AC part of system is connected with DC part through rectifyer valves. Commutation of the valves causes cyclic variation of configuration of the entire galvanically connected network. A distinct feature of AC/DC-IT systems is that voltages between all points of AC side and ground may have mean value different from zero. This characteristic parameter can be used as a signal to determine fault and position to ground or decrease in insulation resistance. However, it also affects the results of the network equivalent insulation resistance measurements when a DC source is used to check insulation. The paper presents a solution to eliminate this effect and proposes a device model to measure and monitor insulation resistance. The results of this study can be applied in the design and manufacture of automatic resistance measuring and monitoring devices for AC/DC mixed unearthed networks.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
ESP Application for Oil Production in Naturally Fractured Granitic Basement Reservoir Comparison analytical hierarchy process (AHP) and frequency ratio (FR) method in assessment of landslide susceptibility. A case study in Van Yen district, Yen Bai province Deep geological structure of An Chau trough base on new study data Assessment of liquefaction potential of sand distributed in the 1 District, Ho Chi Minh city Geotechnical zoning in Hai Duong province for construction planning
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1