导体周围的脉冲电晕放电能量

C. Gary, G. Dragan, I. Langu
{"title":"导体周围的脉冲电晕放电能量","authors":"C. Gary, G. Dragan, I. Langu","doi":"10.1109/IAS.1990.152295","DOIUrl":null,"url":null,"abstract":"Impulse corona discharge around the conductors and the overvoltage wave traveling on an overhead line were experimentally studied. Some of the experiments aimed at establishing a general relation for the charge-voltage characteristic of the coronal discharge around the conductors. During the tests four types of single conductors were used, with 0.010 m, 0.016 m, 0.031 m, and 0.065 m diameters, as well as three types of bundled conductors (with 2, 3, and 4 subconductors having a 0.031 m diameter, the distance between subconductors being 0.4 m). The applied voltage impulses had positive and negative polarity. After analyzing the experimental results and the computing relations, conclusions are drawn on the impulse corona discharge energy.<<ETX>>","PeriodicalId":185839,"journal":{"name":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Impulse corona discharge energy around the conductors\",\"authors\":\"C. Gary, G. Dragan, I. Langu\",\"doi\":\"10.1109/IAS.1990.152295\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Impulse corona discharge around the conductors and the overvoltage wave traveling on an overhead line were experimentally studied. Some of the experiments aimed at establishing a general relation for the charge-voltage characteristic of the coronal discharge around the conductors. During the tests four types of single conductors were used, with 0.010 m, 0.016 m, 0.031 m, and 0.065 m diameters, as well as three types of bundled conductors (with 2, 3, and 4 subconductors having a 0.031 m diameter, the distance between subconductors being 0.4 m). The applied voltage impulses had positive and negative polarity. After analyzing the experimental results and the computing relations, conclusions are drawn on the impulse corona discharge energy.<<ETX>>\",\"PeriodicalId\":185839,\"journal\":{\"name\":\"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-10-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1990.152295\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1990.152295","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

实验研究了导线周围的脉冲电晕放电和架空线路上的过电压波。一些实验旨在建立导体周围的日冕放电的电荷电压特性的一般关系。在试验期间,使用了四种类型的单导体,直径分别为0.010 m、0.016 m、0.031 m和0.065 m,以及三种类型的捆扎导体(2、3和4个直径为0.031 m的子导体,子导体之间的距离为0.4 m)。施加的电压脉冲具有正负极性。通过对实验结果和计算关系的分析,得出了脉冲电晕放电能量的结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impulse corona discharge energy around the conductors
Impulse corona discharge around the conductors and the overvoltage wave traveling on an overhead line were experimentally studied. Some of the experiments aimed at establishing a general relation for the charge-voltage characteristic of the coronal discharge around the conductors. During the tests four types of single conductors were used, with 0.010 m, 0.016 m, 0.031 m, and 0.065 m diameters, as well as three types of bundled conductors (with 2, 3, and 4 subconductors having a 0.031 m diameter, the distance between subconductors being 0.4 m). The applied voltage impulses had positive and negative polarity. After analyzing the experimental results and the computing relations, conclusions are drawn on the impulse corona discharge energy.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of five different approaches for real time digital feedback control of PWM inverters Simulation of power rectifiers in SPICE Interactive simulation of power systems: ETAP applications and techniques A variable frequency soft commutated voltage source inverter delivering sinusoidal waveforms ESD characteristics of a three body system including a ground plane
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1